beautypg.com

Warning, Installation to double wood stud wall – Peerless-AV DS509 - Installation User Manual

Page 4

background image

ISSUED: 04-06-09 SHEET #:125-9059-3 07-11-11

4 of 9

Installation to Double Wood Stud Wall

Wall plate (A) can be mounted to two studs that are 16" apart. Use a stud fi nder to locate the edges of the studs.
Use of an edge-to-edge stud fi nder is highly recommended. Based on their edges, draw a vertical line down
each stud’s center. Place wall plate on wall as a template. Level plate, and mark the center of the four mounting
holes. Make sure that the mounting holes are on the stud centerlines. Drill four 5/32" (4 mm) dia. holes 2-1/2"
(64 mm) deep. Make sure that the wall plate is level, secure it using four #14 x 2.5" wood screws (C) as shown.

Skip to step 2

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all

attached hardware and components.

• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder

is highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-

ers are responsible to provide hardware for other types of mounting situations.

WARNING

C

A

STUD

1