beautypg.com

B&B Electronics HDV100A3 - Manual User Manual

Page 22

background image

18

HDV100A3 Command & Response Manual

B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5104

To stop broadcast transmission it is not necessary to send the whole message.
The message below will stop broadcast transmission.

Byte
Number

Byte
Value

Function

1

01

Start of frame

2

02

Control bytes

3

01

ID byte 1 = J1708 message

4

07

Set broadcast 7 = On X = Time interval (see chart)

7

00

Data bytes

8

0B

Checksum


Byte 4 Values

Byte
Value

Time
Value

07

Stop broadcast

17

.5 sec.

27

1.0 sec

37

1.5 sec

47

2.0 sec

Byte 6 (Priority) Values

Byte Value
(hex)

Byte Value
Binary

Priority

01

00000001

1

02

00000010

2

04

00000100

3

08

00001000

4

10

00010000

5

20

00100000

6

40

01000000

7

80

10000000

8