beautypg.com

Quick start guide – B&B Electronics ZZ24D-NA(NB,NC,ND)-SR - Quick Start Guide User Manual

Page 3

background image

7516R8_ZlinxIO-0812qsg – Peer-to-Peer Mode


P

P

e

e

e

e

r

r

-

-

t

t

o

o

-

-

P

P

e

e

e

e

r

r

M

M

o

o

d

d

e

e

C

C

h

h

e

e

c

c

k

k

f

f

o

o

r

r

A

A

l

l

l

l

R

R

e

e

q

q

u

u

i

i

r

r

e

e

d

d

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

Zlinx I/O Base Module and Expansion Modules

ZZ-PROG1 Configuration Box or ZZ-PROG1-USB

Module

Straight-through serial cable or USB cable if using

a ZZ-PROG1-USB Module

This Quick Start Guide

Zlinx Wireless Modbus I/O Manual on CD (Can be

downloaded from the Web Site)

Zlinx I/O Manager software on CD (Can be downloaded

from the Web Site)

Special Precautions for UL and UL Class I DIV 2

Note 1: Class 1, Div 2 is not applicable to ZZxD-Nx-MR (medium range),

ZZ8D-Nx-xR (800 MHz) and ZZxD-Nx-xR-AU (Australian) modules.

Note 2: For C1D2 information on ZZ-8DO-R, separate sheet is attached.


WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS
MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.

WARNING – EXPLOSION HAZARD – WHEN IN HAZARDOUS
LOCATIONS, TURN OFF POWER BEFORE REPLACING ANTENNA.

WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT
UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN
TO BE NONHAZARDOUS.

THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2,
GROUPS A, B, C, AND D, OR UNCLASSIFIED LOCATIONS.

Maximum Ambient Air Temperature 80°C (176°F) except for ZZ-8DO-R.

Wiring Terminals:
Copper Wire Only
One Conductor per Terminal
Wire Range 28 to 16 AWG
Tightening Torque 1.7 lb-in
Temperature Rating of Field Wiring – 105° C (221° F) minimum sized for
60° C (140°F) ampacity.

Warning – 2 DIN rail end brackets (supplied with each expansion
module) must be installed, one on each end of the assembled system on
the DIN rail to mechanically secure the individual products.

S

S

e

e

l

l

e

e

c

c

t

t

M

M

o

o

d

d

u

u

l

l

e

e

s

s

Select the Base and Expansion Modules required for the

location and coverage distances

Ensure that two systems are complementary, i.e. the inputs

of the Modules in System 1 (see figure below) match the

outputs of the corresponding Modules in System 2.

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

Perform an installation site survey to ensure adequate

RF coverage and select a mounting location.

Maximum Ambient Air Temperature for all modules is

80°C, with the exception of the ZZ-8DO-R, which is 65°C

Mount and connect together two systems of the Base

and Expansion Modules (Expansion Modules on the right

side of the Base).

Ensure that the Modules are attached properly.

Plug the Configuration Box into the right side of the

system.

Attach the antennas to the Base Modules.

Connect field wiring to Zlinx I/O terminals.

Refer to the Installation Manual for power and wattage

requirements

C

C

o

o

n

n

n

n

e

e

c

c

t

t

F

F

i

i

e

e

l

l

d

d

W

W

i

i

r

r

i

i

n

n

g

g

Refer to the User Manual for Input / Output Voltage and

Current Ratings

I

I

n

n

s

s

t

t

a

a

l

l

l

l

Z

Z

l

l

i

i

n

n

x

x

I

I

/

/

O

O

S

S

o

o

f

f

t

t

w

w

a

a

r

r

e

e

Insert the I/O Manager software CD. Installation should

launch automatically. If not, click Start, Run,

[drive]:\ZlinxMgr.exe, where [drive] is your CD-Rom drive.

Follow the prompts to install the Zlinx I/O Manager.

S

S

t

t

a

a

r

r

t

t

Z

Z

l

l

i

i

n

n

x

x

I

I

/

/

O

O

M

M

a

a

n

n

a

a

g

g

e

e

r

r

Connect a PC serial port (COM1 to 16) to the

Configuration Box using a straight-through serial cable or

USB cable if using a ZZ-PROG1-USB module

Click Start\Programs\B&B Electronics\Zlinx\Zlinx

Manager\Zlinx Manager, then click Zlinx I/O and then

Zlinx I/O Configuration. It will auto-search for attached

Quick Start Guide

Zlinx™ I/O

1

3

4

2

5

6

System 1

System 2