beautypg.com

Typical operating characteristics, Electrical characteristics (continued) – Rainbow Electronics MAX1636 User Manual

Page 5

background image

MAX1636

Low-Voltage, Precision Step-Down

Controller for Portable CPU Power

_______________________________________________________________________________________

5

ELECTRICAL CHARACTERISTICS (continued)

(Circuit of Figure 1, V+ = 15V, SYNC = VL = V

CC

, I

VL

= 0mA, I

REF

= 0mA, T

A

= -40°C to +85°C, unless otherwise noted.) (Note 1)

FB, with respect to regulation point

Guaranteed by design

SYNC = GND

SYNC = V

CC

%

3.5

10

Oscillator Frequency

ns

SYNC Input Pulse Width High

Overvoltage Trip Threshold

kHz

240

340

SYNC Input Frequency Range

%

ns

200

SYNC Input Rise/Fall Time

ns

200

SYNC Input Pulse Width Low

SHDN, SKIP, OVP, SYNC

SHDN, SKIP, OVP, SYNC

200

Falling edge (hysteresis = 1%)

% of nominal output

V

0.4

RESET Output Voltage Low

V

0.8

V

170

230

2.4

270

330

Logic Input Voltage High

kHz

Logic Input Voltage Low

%

-7 -1.5

RESET Trip Threshold

Catastrophic Output Undervoltage
Lockout Threshold

60

80

I

SINK

= 4mA

High or low, DH or DL

7

Gate-Driver On-Resistance

CONDITIONS

UNITS

MIN

TYP

MAX

PARAMETER

OSCILLATOR

OVERVOLTAGE PROTECTION

INPUTS AND OUTPUTS

__________________________________________Typical Operating Characteristics

(Circuit of Figure 1, V

IN

= 7V, T

A

= +25°C, unless otherwise noted.)

100

50

1m

100m

1

10m

10

EFFICIENCY vs. LOAD CURRENT

(3.3V/3A CIRCUIT)

60

MAX1636 TOC01

LOAD CURRENT (A)

EFFICIENCY (%)

70

80

90

V

IN

= 22V

V

IN

= 30V

V

IN

= 7V

V

IN

= 15V

100

50

1m

100m

1

10m

10

EFFICIENCY vs. LOAD CURRENT

(5V/3A CIRCUIT)

60

MAX1636 TOC02

LOAD CURRENT (A)

EFFICIENCY (%)

70

80

90

V

IN

= 22V

V

IN

= 7V

V

IN

= 15V

V

IN

= 30V

100

50

1m

100m

1

10m

10

EFFICIENCY vs. LOAD CURRENT

(1.8V/1A CIRCUIT)

60

MAX1636 TOC03

LOAD CURRENT (A)

EFFICIENCY (%)

70

80

90

V

IN

= 15V

V

IN

= 7V

V

IN

= 22V

Note 1: Specifications to -40°C are guaranteed by design and not production tested.