beautypg.com

Shift register mode timing waveforms, Ac testing input/output waveforms(1), Float waveforms(1) – Rainbow Electronics AT89C51RC User Manual

Page 22: At89c51rc, Float waveform s

background image

AT89C51RC

22

Shift Register Mode Timing Waveforms

AC Testing Input/Output Waveforms

(1)

Note:

1.

AC Inputs during testing are driven at V

CC

- 0.5V

for a logic 1 and 0.45V for a logic 0. Timing mea-
surements are made at V

IH

min. for a logic 1 and V

IL

max. for a logic 0.

Float Waveforms

(1)

Note:

1.

For timing purposes, a port pin is no longer floating
when a 100 mV change from load voltage occurs. A
port pin begins to float when a 100 mV change from
the loaded V

OH

/V

OL

level occurs.

Serial Port Timing: Shift Register Mode Test Conditions

The values in this table are valid for V

CC

= 4.0V to 5.5V and Load Capacitance = 80 pF.

Symbol

Parameter

12 MHz Osc

Variable Oscillator

Units

Min

Max

Min

Max

t

XLXL

Serial Port Clock Cycle Time

1.0

12t

CLCL

µs

t

QVXH

Output Data Setup to Clock Rising Edge

700

10t

CLCL

- 133

ns

t

XHQX

Output Data Hold after Clock Rising Edge

50

2t

CLCL

- 80

ns

t

XHDX

Input Data Hold after Clock Rising Edge

0

0

ns

t

XHDV

Clock Rising Edge to Input Data Valid

700

10t

CLCL

- 133

ns

t

XHDV

t

QVXH

t

XLXL

t

XHDX

t

XHQX

ALE

INPUT DATA

CLEAR RI

OUTPUT DATA

WRITE TO SBUF

INSTRUCTION

CLOCK

0

0

1

1

2

2

3

3

4

4

5

5

6

6

7

7

SET TI

SET RI

8

VALID

VALID

VALID

VALID

VALID

VALID

VALID

VALID

0.45V

TEST POINTS

V - 0.5V

CC

0.2 V + 0.9V

CC

0.2 V - 0.1V

CC

V

LOAD

+ 0.1V

Timing Reference

Points

V

LOAD

- 0.1V

LOAD

V

V

OL

+ 0.1V

V

OL

- 0.1V