Shift register mode timing waveforms, Ac testing input/output waveforms(1), Float waveforms(1) – Rainbow Electronics AT89C51RC User Manual
Page 22: At89c51rc, Float waveform s
AT89C51RC
22
Shift Register Mode Timing Waveforms
AC Testing Input/Output Waveforms
Note:
1.
AC Inputs during testing are driven at V
CC
- 0.5V
for a logic 1 and 0.45V for a logic 0. Timing mea-
surements are made at V
IH
min. for a logic 1 and V
IL
max. for a logic 0.
Float Waveforms
Note:
1.
For timing purposes, a port pin is no longer floating
when a 100 mV change from load voltage occurs. A
port pin begins to float when a 100 mV change from
the loaded V
OH
/V
OL
level occurs.
Serial Port Timing: Shift Register Mode Test Conditions
The values in this table are valid for V
CC
= 4.0V to 5.5V and Load Capacitance = 80 pF.
Symbol
Parameter
12 MHz Osc
Variable Oscillator
Units
Min
Max
Min
Max
t
XLXL
Serial Port Clock Cycle Time
1.0
12t
CLCL
µs
t
QVXH
Output Data Setup to Clock Rising Edge
700
10t
CLCL
- 133
ns
t
XHQX
Output Data Hold after Clock Rising Edge
50
2t
CLCL
- 80
ns
t
XHDX
Input Data Hold after Clock Rising Edge
0
0
ns
t
XHDV
Clock Rising Edge to Input Data Valid
700
10t
CLCL
- 133
ns
t
XHDV
t
QVXH
t
XLXL
t
XHDX
t
XHQX
ALE
INPUT DATA
CLEAR RI
OUTPUT DATA
WRITE TO SBUF
INSTRUCTION
CLOCK
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
SET TI
SET RI
8
VALID
VALID
VALID
VALID
VALID
VALID
VALID
VALID
0.45V
TEST POINTS
V - 0.5V
CC
0.2 V + 0.9V
CC
0.2 V - 0.1V
CC
V
LOAD
+ 0.1V
Timing Reference
Points
V
LOAD
- 0.1V
LOAD
V
V
OL
+ 0.1V
V
OL
- 0.1V