DS2422/DS2423

8 of 25

important to realize that the target address registers will contain the address provided. The ending
offset/data status byte is unaffected.

The hardware of the DS242X provides a means to accomplish error-free writing to the memory section.
To safeguard reading data in the 1-Wire environment and to simultaneously speed up data transfers, it is
recommended to packetize data into data packets of the size of one memory page each. Such a packet
would typically store a 16-bit CRC with each page of data to ensure rapid, error-free data transfers that
eliminate having to read a page multiple times to determine if the received data is correct or not. (See the
Book of DS19xx iButton Standards, Chapter 7 for the recommended file structure.)

Read Memory + Counter [A5H]

The Read Memory + Counter command is used to read memory data together with the write cycle counter
or externally triggered counter associated with the addressed page of data memory. The additional
information is transmitted by the DS242X as the end of a memory page is encountered. Following the
current value of the counter the DS242X transmits 32 0-bits and a 16-bit CRC generated by the DS242X.

After having sent the command code of the Read Memory + Counter command, the bus master sends a
two-byte address (TA1 = (T7:T0), TA2 = (T15:T8)) that indicates a starting byte location within the data
field. With the subsequent read data time slots the master receives data from the DS242X starting at the
initial address and continuing until the end of a 32-byte page is reached. At that point the bus master will
send 80 additional read data time slots and receive the contents of the 32-bit counter associated with the
addressed page, 32 0-bits and a 16-bit CRC. With subsequent read data time slots the master will receive
data starting at the beginning of the next page followed by the contents of the counter associated with the
page, 0-bits and CRC for that page. This sequence will continue until the final page and its accompanying
data is read by the bus master. When applying the Read Memory + Counter command to a page that does
not have a counter associated, the master will read FFFFFFFFH instead of a valid count.

With the initial pass through the Read Memory + Counter flow chart the 16-bit CRC value is the result of
shifting the command byte into the cleared CRC generator, followed by the two address bytes, the
contents of the data memory, the counter and the 0-bits. Subsequent passes through the Read Memory +
Counter flow chart will generate a 16-bit CRC that is the result of clearing the CRC generator and then
shifting in the contents of the data memory page, its associated counter and 0-bits. After the 16-bit CRC
of the last page is read, the bus master will receive logical 1s from the DS242X until a Reset Pulse is
issued. The Read Memory + Counter command sequence can be ended at any point by issuing a Reset
Pulse.