NOTES:
1. All voltages are referenced to ground.
2. Measured with outputs open.
3. V
PUP
= external pullup voltage.
4. Input load is to ground.
5. Read data setup time refers to the time the host must pull the 1-Wire bus low to read a bit. Data is
guaranteed to be valid within 1 µs of this falling edge.
6. Under certain low voltage conditions V
IL1MAX
may have to be reduced to as much as 0.5V to always
guarantee a presence pulse.
7. The reset low time (t
RSTL
) should be restricted to a maximum of 960µs, to allow interrupt signaling,
otherwise, it could mask or conceal interrupt pulses.
8. When V
DD
ramps up, the oscillator is always off.
9. At V
DD
= 3V ± 10%
10. At V
DD
= 5V ± 10%
11.
V
IH1
has to be V
DD
– 0.3V or higher.
12. The optimal sampling point for the master is as close as possible to the end time of the 15µs t
RDV
period without exceeding t
RDV
. For the case of a Read-One Time Slot, this maximizes the amount of
time for the pull-up resistor to recover to a high level. For a Read-Zero Time Slot, it ensures that a
read will occur before the fastest 1-Wire device(s) release the line.
13. The duration of the low pulse sent by the master should be a minimum of 1µs with a maximum value
as short as possible to allow time for the pull-up resistor to recover the line to a high level before the
1-Wire device samples in the case of a Write-One Time or before the master samples in the case of a
Read-One Time.