Modectrl register – Rainbow Electronics AT77C104B User Manual
Page 13

13
AT77C104B
5347B–BIOM–08/04
Modectrl Register
Register Name:Modectrl (7 bits)
Access Type:Read/Write
Function:Mode control
•
MODE: select operating mode
0000: standby
0001: test (reserved for factory use)
0010: click
0100: navigation
1000: acquisition
Certain changes can be made. For example, MODE can be set to 0b0110 to activate
click and navigation.
•
ANALOGRST: reset local oscillator
0: oscillator in active mode
1: oscillator in power-down mode
Notes:
1. Click or navigation modes cannot be used when the local oscillator is switched off. .
2. To return to standby mode and stop the oscillator (to save on power consumption),
two Modectrl register accesses are
necessary: the first one to select standby mode and the second to switch off the
oscillator.
3. The read-only registers cannot be read when the oscillator is turned off.
4. To shift between navigation and acquisition modes, you must be in standby mode
(Modectrl = 0b00001).
If modes such as “acquisition and click” or “acquisition and navigation” are programmed
together, they will be ignored by the system.
With x = 0 or 1.
b6
b5
b4
b3
b2
b1
b0
MODE (MSB)
MODE
MODE
MODE (LSB)
ANALOGRST
–
–
0
0
0
0
1
0
0
Programmed Mode
Register Value
11xx
01xx
1x1x
0x1x