Rainbow Electronics DS1615 User Manual
Page 6
DS1615
6 of 24
DS1615 RTC AND CONTROL PAGE Figure 2b
ADDRESS BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
FUNCTION
00
0
10 Seconds
Single Seconds
01
0
10 Minutes
Single Minutes
10
02
0
12/24
A/P
10 h
Single Hours
03
0
0
0
0
0
Day Of Week
04
0
0
10 Date
Single Date
05
0
0
0
10 m.
Single Month
06
10 Years
Single Years
Real Time Clock
Registers
07
MS
10 Seconds Alarm
Single Seconds Alarm
08
MM
10 Minutes Alarm
Single Minutes Alarm
10 h
09
MH
12/24
A/P
10 h
alm
Single Hours Alarm
0A
MD
0
0
0
0
Day Of Week Alarm
Real Time Alarm
Clock
0B
Low Temperature Threshold
0C
High Temperature Threshold
Temperature
Alarm
0D
Number Of Minutes Between Temperature Conversions
Sample Rate
0E
EOSC
CLR
0
SE
RO
TLIE
THIE
AIE
Control
0F
(reads 00h)
Reserved
10
(reads 00h)
Reserved
11
Current Temperature
Temperature
12
Start Delay Register (LSB)
Start Delay
13
Start Delay Register (MSB)
Start Delay
14
TR
MEM
CLR
MIP
SIP
LOBAT
TLF
THF
ALMF
Status
15
Minutes
16
Hours
17
Date
18
Month
19
Year
Start Time Stamp
1A
Low Byte
1B
Medium Byte
1C
High Byte
Current Samples
Counter
1D
Low Byte
1E
Medium Byte
1F
High Byte
Total Samples
Counter
20-3F
(Read 00H)
Reserved