2.3 Installation

The

Telit GT863-PY

can be fixed on a suitable surface by two screws through the holes (3,3 / 5,8

mm diam.) in the lids forming part of the front and rear panels. The figure shows the maximum and
minimum inter-axis distance between the fixing holes.
In case of a permanent vertical installation in dusty environment, it is recommended to cover the
SIM slot with a self-adhesive tape.

2.4 Environmental requirements

The

Telit GT863-PY

is compliant with the applicable ETSI reference documentation GSM 05.05

Release1999 ETSI EN300910 V8.4.1

2.4.1 Temperature range

• Temperature in normal functional conditions –10°C ÷ +55°C
• Temperature in extreme functional conditions* –20°C ÷ +70°C
• Temperature in storage conditions

–30°C

÷ +85°C

Temperature exceeding the range of normal functional conditions can affect the sensitivity and
performance of the modem.

2.4.2 RoHS compliance

The

GT863-PY

is fully RoHS compliant to EU regulation.