background image

MAX6660

Remote-Junction Temperature-Controlled
Fan-Speed Regulator with SMBus Interface

10

______________________________________________________________________________________

The SMBus interface includes a Timeout, which resets
the interface any time the data or clock line is held low
for more than 35ms, ensuring that the MAX6660 can
never “lock” the bus.

Remote Temperature Data Register

Two registers, at addresses 00h and 01h, store the
measured temperature data from the remote diode. The
data format for the remote-diode temperature is 10 bit
+ sign, with each bit corresponding to 0.125°C, in two’s
complement format (Table 2). Register 01h contains the
sign bit and the first 7 bits. Bits 7, 6, 5 of Register 00h
are the 3LSBs. If the two registers are not read at the
same time, their contents may be the result of two dif-
ferent temperature measurements leading to erroneous
temperature data. For this reason, a parity bit has been
added to the 00h register. Bit 4 of this is zero if the data
in 00h and 01h are from the same temperature conver-
sion and are 1 if they are not. The remaining bits are
“don’t cares.” When reading temperature data, register
01h must be read first.

Alarm Threshold Registers

The MAX6660 provides four alarm threshold registers
that can be programmed with a two’s complement tem-
perature value with each bit corresponding to 1°C. The
registers are T

HIGH

, T

LOW

, T

MAX

, and T

HYST

. If the

measured temperature equals or exceeds T

HIGH

, or is

less than T

LOW

, an

ALERT interrupt is asserted. If the

measured temperature equals or exceeds T

MAX

, the

OVERT output is asserted (see Over-Temperature
Output (

OVERT)

section). If

ALERT and OVERT are acti-

vated by the temperature exceeding T

MAX

, they can

only be deasserted by the temperature dropping below
T

HYST

. The POR state for T

HIGH

is +127°C, for T

LOW

is -

55°C, for T

MAX

is +100°C, and for T

HYST

is +95°C.

Over-Temperature Output (

OVERT

)

The MAX6660 has an over-temperature output (

OVERT)

that is set when the remote-diode temperature crosses
the limits set in the T

MAX

register. It is always active if

the remote-diode temperature exceeds T

MAX

. The

OVERT line clears when the temperature drops below
T

HYST

. Bit 1 of the Configuration register can be used

to mask the

OVERT output. Typically, the OVERT output

is connected to a power-supply shutdown line to turn
system power off. At power-up,

OVERT defaults to

active-low but the polarity can be reversed by setting
bit 5 of the Configuration register.

The

OVERT line can be taken active, either by the

MAX6660 or driven by an external source. An external
source can be masked by bit 2 of the Configuration
register. When

OVERT is active, the fan loop forces the

fan to full speed and bit 1 of the Status register is set.

Diode Fault Alarm

A continuity fault detector at DXP detects an open cir-
cuit between DXP and DXN. If an open or short circuit
exists, register 01h is loaded with 000 0000.
Additionally, if the fault is an open circuit, bit 2 of the
status byte is set to 1 and the ALERT condition is acti-
vated at the end of the conversion. Immediately after
POR, the Status register indicates that no fault is pre-
sent until the end of the first conversion.

ALERT

Interrupts

The

ALERT interrupt output signal is activated (unless it

is masked by bit 7 in the Configuration register) when-
ever the remote-diode’s temperature is below T

LOW

or

exceeds T

HIGH

. A disconnected remote diode (for con-

tinuity detection), a shorted diode, or an active

OVERT

also activates the ALERT signal. The activation of the

ALERT signal sets the corresponding bits in the Status
register. There are two ways to clear the

ALERT: send-

ing the ALERT Response Address or reading the Status
register.

The interrupt does not halt automatic conversions. New
temperature data continues to be available over the
SMBus interface after

ALERT is asserted. ALERT is an

active-low open-drain output so that devices can share
a common interrupt line. The interrupt is updated at the
end of each temperature conversion so, after being
cleared, reappears after the next temperature conver-
sion, if the cause of the fault has not been removed.

By setting bit 0 in the Configuration register to 1, the
Status register can only be cleared by sending the
SMBus Alert Response Address (see Alert Response
Address
section). Prior to taking corrective action,
always check to ensure that an interrupt is valid by
reading the current temperature. To prevent recurring
interrupts, the MAX6660 asserts

ALERT only once per

crossing of a given temperature threshold. To enable a
new interrupt, the value in the limit register that trig-
gered the interrupt must be rewritten. Other interrupt
conditions can be caused by crossing the opposite
temperature threshold, or a diode fault can still cause
an interrupt.

Example: The remote temperature reading crosses
T

HIGH

, activating

ALERT. The host responds to the

interrupt and reads the Alert Response Address, clear-
ing the interrupt. The system may also read the status
byte at this time. If the condition persists, the interrupt
reappears. Finally, the host writes a new value to
T

HIGH

. This enables the device to generate a new

T

HIGH

interrupt if the alert condition still exists.