beautypg.com

Rainbow Electronics MAX6796 User Manual

Page 10

background image

MAX6791–MAX6796

High-Voltage, Micropower, Single/Dual Linear
Regulators with Supervisory Functions

10

______________________________________________________________________________________

Pin Description

Typical Operating Characteristics (continued)

(V

IN

= V

EN

= 14V, C

IN

= 0.1µF, C

OUT

= 10µF, T

J

= T

A

= +25°C, unless otherwise noted.)

LOAD-TRANSIENT RESPONSE

MAX6791-96toc21

OUT1

AC-COUPLED

I

OUT1

100mA/div

1mA

500mV/div

1ms/div

MAX6792
OUT1 = 5V
C

OUT

= 10

µF

LOAD-TRANSIENT RESPONSE

MAX6791-96toc22

I

OUT1

OUT1

AC-COUPLED

100mA/div

20mA

500mV/div

1ms/div

MAX6792
OUT1 = 5V
C

OUT

= 10

µF

PIN

MAX6791/

MAX6792

MAX6793/

MAX6794

MAX6795/

MAX6796

NAME

FUNCTION

1, 2

1, 2

OUT1

Reg ul ator 1 Outp ut. Fi xed ( + 1.8V , + 2.5V , + 3.3V , or + 5V ) or ad j ustab l e ( + 1.8V to
+ 11V ) . OU T1 = 150m A ( m ax) . C onnect a 10µF ( m i n) cap aci tor fr om OU T1 to GN D .

3

3

SET1

Feed b ack Inp ut for S etti ng the O U T1 V ol tag e. C onnect S E T1 to GN D to sel ect the
p r eset outp ut vol tag e. C onnect to an exter nal r esi sti ve d i vi d er for ad j ustab l e
outp ut op er ati on.

4

4

4

PFO

Active-Low, Open-Drain, Power-Fail Comparator Output. PFO asserts low
when PFI is below the internal 1.231V threshold. PFO deasserts when PFI is
above the internal 1.231V threshold.

5

5

5

CSWT

Watchd og Ti m eout P er i od Ad j ust Inp ut. C onnect C S WT to OU T1/OU T for the
i nter nal l y fi xed w atchd og ti m eout p er i od . For ad j ustab l e w atchd og ti m eout p er i od ,
connect a cap aci tor fr om C S WT to GN D . C onnect C S WT to GN D to d i sab l e the
w atchd og . S ee the S el ecti ng Watchd og Ti m eout P er i od secti on for m or e d etai l s.

6

6

6

CSRT

Reset Timeout Period Adjust Input. Connect CSRT to OUT1/OUT for the
internally fixed timeout period. For adjustable timeout, connect a capacitor
from CSRT to GND. See the Reset Output section for more details.

7

7

7

GND

Ground

8

8

8

RESET

Acti ve- Low Reset Outp ut. RES ET r em ai ns l ow w hi l e OU T1/OU T i s b el ow the r eset
thr eshol d . RES ET r em ai ns l ow for the d ur ati on of the r eset ti m eout p er i od after the
r eset cond i ti ons end . RES ET i s avai l ab l e i n p ush- p ul l and op en- d r ai n op ti ons.