beautypg.com

Absolute maximum ratings, Electrical characteristics – Rainbow Electronics MAX6696 User Manual

Page 2

background image

MAX6695/MAX6696

Dual Remote/Local Temperature Sensors with
SMBus Serial Interface

2

_______________________________________________________________________________________

ABSOLUTE MAXIMUM RATINGS

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.

V

CC

...........................................................................-0.3V to +6V

DXP1, DXP2................................................-0.3V to (V

CC

+ 0.3V)

DXN ......................................................................-0.3V to +0.8V
SMBCLK, SMBDATA, ALERT ...................................-0.3V to +6V
RESET, STBY, ADD0, ADD1, OT1, OT2 ...................-0.3V to +6V
SMBDATA Current .................................................1mA to 50mA
DXN Current ......................................................................±1mA

Continuous Power Dissipation (T

A

= +70°C)

10-Pin mMAX (derate 6.9mW/°C above +70°C) .......555.6mW
16-Pin QSOP (derate 8.3mW/°C above +70°C) .......666.7mW

Operating Temperature Range .........................-40°C to +125°C
Junction Temperature .....................................................+150°C
Storage Temperature Range ............................-65°C to +150°C
Lead Temperature (soldering, 10s) ................................+300°C

ELECTRICAL CHARACTERISTICS

(V

CC

= +3.0V to +3.6V, T

A

= 0°C to +125°C, unless otherwise noted. Typical values are at V

CC

= +3.3V and T

A

= +25°C)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Supply Voltage

V

CC

3.0

3.6

V

Standby Supply Current

SMBus static, ADC in idle state

10

µA

Operating Current

Interface inactive, ADC active

0.5

1

mA

Conversion rate = 0.125Hz

35

70

Conversion rate = 1Hz

250

500

Average Operating Current

Conversion rate = 4Hz

500

1000

µA

T

RJ

= +25°C to +100°C

(T

A

= +45°C to +85°C)

-1.5

+1.5

T

R J

= 0° C to + 125° C ( T

A

= + 25° C to + 100° C ) -3.0

+3.0

T

RJ

= -40°C to +125°C (T

A

= 0°C to +125°C)

-5.0

+5.0

Remote Temperature Error
(Note 1)

T

RJ

= -40°C to +125°C (T

A

= -40°C)

+3.0

°C

T

A

= +45°C to +85°C

-2.0

+2.0

T

A

= +25°C to +100°C

-3.0

+3.0

T

A

= 0°C to +125°C

-4.5

+4.5

Local Temperature Error

T

A

= -40°C to +125°C

+3.0

°C

Power-On Reset Threshold

V

CC

, falling edge (Note 2)

1.3

1.45

1.6

V

POR Threshold Hysteresis

500

mV

Undervoltage Lockout Threshold

UVLO

Falling edge of V

CC

disables ADC

2.2

2.8

2.95

V

Undervoltage Lockout Hysteresis

90

mV

Channel 1 rate

≤4Hz, channel 2 / local rate

≤2Hz (conversion rate register ≤05h)

112.5

125

137.5

Conversion Time

Channel 1 rate

≥8Hz, channel 2 / local rate

≥4Hz (conversion rate register ≥06h)

56.25

62.5

68.75

ms

High level

80

100

120

Remote-Diode Source Current

I

RJ

Low level

8

10

12

µA

ALERT

,

OT1

,

OT2

Output Low Sink Current

V

OL

= 0.4V

6

mA

Output High Leakage Current

V

OH

= 3.6V

1

µA

INPUT PIN, ADD0, ADD1 (MAX6696)

Logic Input Low Voltage

V

IL

0.3

V

Logic Input High Voltage

V

IH

2.9

V