MAX6695/MAX6696
Dual Remote/Local Temperature Sensors with
SMBus Serial Interface
______________________________________________________________________________________
11
REGISTER
ADDRESS
POR STATE
FUNCTION
RLTS
00 h
0000 0000
(0
°C)
Read internal temperature
RRTE
01 h
0000 0000
(0
°C)
Read external
channel 1
temperature if bit 3 of configuration register is
0
;
Read external
channel 2
temperature if bit 3 of configuration register is
1
RSL1
02 h
1000 0000
Read status register 1
RCL
03 h
0000 0000
Read configuration byte (fault queue should be disabled at startup)
RCRA
04 h
0000 0110
Read conversion rate byte
RLHN
05 h
0100 0110
(+70
°C)
Read internal ALERT high limit
RLLI
06 h
1100 1001
(-55
°C)
Read internal ALERT low limit
RRHI
07 h
0100 0110
(+70
°C)
Read external
channel 1
ALERT high limit if bit 3 of configuration register is
0
;
Read external
channel 2
ALERT high limit if bit 3 of configuration register is
1
RRLS
08 h
1100 1001
(-55
°C)
Read external
channel 1
ALERT low limit if bit 3 of configuration register is
0
;
Read external
channel 2
ALERT low limit if bit 3 of configuration register is
1
WCA
09 h
0010 0000
Write configuration byte
WCRW
0A h
0000 0110
Write conversion rate byte
WLHO
0B h
0100 0110
(+70
°C)
Write internal ALERT high limit
WLLM
0C h
1100 1001
(-55
°C)
Write internal ALERT low limit
WRHA
0D h
0100 0110
(+70
°C)
Write external
channel 1
ALERT high limit if bit 3 of configuration register is
0
;
Write external
channel 2
ALERT high limit if bit 3 of configuration register is
1
WRLN
0E h
1100 1001
(-55
°C)
Write external
channel 1
ALERT low limit if bit 3 of configuration register is
0
;
Write external
channel 2
ALERT low limit if bit 3 of configuration register is
1
OSHT
0F h
0000 0000
One shot
REET
10 h
0000 0000
Read extended temp of external
channel 1
if bit 3 of configuration register is
0
;
Read extended temp of external
channel 2
if bit 3 of configuration register is
1
RIET
11 h
0000 0000
Read internal extended temperature
RSL2
12 h
0000 0000
Read status register 2
RWO2E
16 h
0111 1000
(+120
°C)
Read/write external OT2 limit for
channel 1
if bit 3 of configuration register is
0
;
Read/write external OT2 limit for
channel 2
if bit 3 of configuration register is
1
RWO2I
17 h
0101 1010
(+90
°C)
Read/write internal OT2 limit
RWO1E
19 h
0101 1010
(+90
°C)
Read/write external OT1 limit for
channel 1
if bit 3 of configuration register is
0
;
Read/write external OT1 limit for
channel 2
if bit 3 of configuration register is
1
RWO1I
20 h
0100 0110
(+70
°C)
Read/write internal OT1 limit
Table 5. Command-Byte Register Bit Assignments