beautypg.com

Laminar filter – OMAX Laminar Filter User Manual

Page 2

background image

LAMINAR FILTER

When cleaning the tank, the removable angled plate module
can be lifted from the accessory unit. An operator can clean out
the sediment from under the stationary angled plates by using the
Special Sediment Rake.

SYSTEM SPECIFICATIONS

Submersible pump: 120 V, 60 Hz, 1 PH, ¼ hp or less, thermally protected,

cord-connected, with GFCI, UL or CSA

10 ft hose and fittings for sending clean water to a Closed Loop System or

down the drain

15 ft sediment pump hose with Splash Diverter

OPTIONS

Submersible pump: 220 V, 50 Hz, 1 PH, ¼ hp or less, thermally protected,

cord-connected, with PRCD, CE-marked

HIGHLIGHTS

Convenient hose for directing clean water to a Closed Loop System or drain

Rust-proof construction

Complete cleaning system includes Sediment Pump, Splash Diverter, and

Special Sediment Rake

Hose and Splash Diverter are conveniently stored inside the Laminar Filter tank

Water Filtration Process: Red/blue arrows indicate a slow moving,
laminar water flow ideal for the maximum settling of small and lightweight
particles

Exit to drain

or Closed

Loop System

Removable module of

angled plates

Pump outlet hose

to move sediment

laden water to the

Dump Hopper or

Catcher Tank

(Stowed during

normal operation)

Water entry

from Catcher

Tank

Submersible

Sediment

Pump

Angled filter

plates

Splash

Diverter

Special

Sediment Rake

Stationary

module of

angled plates

OMAX CORPORATION

21409 72nd Avenue South

Kent, WA 98032

TEL

1-253-872-2300

/

1-800-838-0343

FAX

1-253-872-6190

WWW.OMAX.COM

Made in the USA

Specifications subject to change without notice.

600065B January 2014