beautypg.com

9931-emde function submenu list and descriptions – Cobalt Digital FUSION 3G 9931-EMDE 3G_HD_SD-SDI Embedder_De-Embedder User Manual

Page 108

background image

3

9931-EMDE Function Submenu List and Descriptions

3-56

9931-EMDE PRODUCT MANUAL

9931-EMDE-OM (V1.15)

Audio Silence

Audio Silence Configuration allows definition of up to 16
embedded audio silence patterns to be detected as
Condition C of the overall Events-Based loading.

Table 3-2

9931-EMDE Function Submenu List — continued

• • •

In the example here (and also correlating to the example on the previous page), Audio Silence Event 1 is set to trigger if audio
on Emb Ch 3 thru Ch 6 falls below the selected threshold for an interval exceeding the selected threshold (for example, a
reversion to stereo audio instead of 5.1-channel audio).

If Audio Silence Event as a trigger condition is not desired, it can be set to Don’t Care on the Event Based Loading sub-tab, or
globally set to Disabled here.

Failover controls set the conditions that comprise a silence event, and also a transition back to an untriggered condition with
resumption of audio for the selected embedded channels.

• If the selected channels maintain levels above the selected Audio Failover Threshold, no triggering is invoked.

• If these channels fall below the selected threshold for period specified by the Primary to Secondary Holdoff control, the

respective Audio Silence Event trigger (condition C) goes true.

Secondary to Primary Holdoff control sets the time in which the trigger is revoked upon an event false condition.

Note: Default threshold and holdoff settings shown here are recommended for typical use.