Cabling for the 9216-OE-DM

This section provides information for connecting cables to the installed Rear Modules on the 20-slot
frames. Connect the input and output cables according to the following sections.

The optical connector used to mate the card to the rear module is designed for blind mate optical
connectors. All fiber interfaces are single mode fibers.

Notice

— Never attempt to look down the barrel of a connected fiber or device

transmitting an optical signal. The transmitted light is not in the visible spectrum and
may cause permanent eye damage. Turn off all laser sources before disconnecting
devices.

20-Slot Frame Cabling Overview

In the 20-slot frames, the 9216-OE-DM is used with the RM20-9216-B Full Rear Module. Each card
occupies two slots and provides one fiber input, one SDI input, one SDI output, and eight AES
unbalanced outputs at 75ohm. ( Figure 2.4 )

Note

— You must use the Setup tab in DashBoard to specify which SDI Source to use

as the input (BNC or Optical Port).

Figure 2.4 Cable Connections for the RM20-9216-B Rear Module