Setup screens, Chapter 4 setup screens, Special network dryer setup screens – Grain Systems PNEG-1181 User Manual
Page 13

PNEG-1181 Portable Dryer Troubleshooting
13
4. Setup Screens
Special Network Dryer Setup Screens
There are certain dryer features that rarely need to be changed and which should be carefully considered
before adjusting. To access these advanced features, with the power OFF, press and hold the MODIFY
button and then turn ON the control power for the dryer. Release the MODIFY button and the advanced
feature screens will be available.
Pressing ENTER after releasing the Modify button will allow you to view and/or change the special setup
screens in the following sequential order:
Selections in bold are the default settings
Series 2000 Fan and Heater Dip Switch Settings:
NOTE: These are set at the factory but will need to be reset when changing out a board.
Fan 1 #1 OFF / All Others ON
Fan 2 #2 OFF / All Others ON
Fan 3 #1 and #2 OFF / All Others ON
Fan 4 #3 OFF / All Others ON
Fan 5 #1 and #3 OFF / All Others ON
Fan 6 #2 and #3 OFF / All Others ON
Option
Select
1. Turn Meter Rolls OFF
No——Yes
2. Air Switch Testing
Yes——No
3. Meter Roll Reverse
No——Yes
A. Reverse Time
5 Minutes, but is adjustable
B. Forward Time
55 Minutes, but is adjustable
4. Select Unload Method
2 Speed——3 Speed
5. Select Dryer Address
01——for use with the Watchdog program only
6. Attempt to Refill
No——Yes
7. Enter Model Number
Dryer Model Number NOTE: Dryer Model Number must
be exact in order for the dryer to operate properly.
8. Temperature Scale
Fahrenheit——Celsius
9. Change Burner Setup
Enter to Change——Reset to Bypass
A. High/Low Fire or ON/OFF Fire
High/Low Fire——ON/OFF Fire
B. Active or Inactive
Active——Inactive
10. Set Time and Date
Time and Date
11. Load System
End Fill——Center Fill——Dual Fill
12. Unit of Measure
Bushels——Metric Tons
13. Change Burner Differential
Enter to Change——Reset to Bypass
A. Set Burner Differential in Degrees
Default is 3 Degrees in High/Low and 1° in ON/OFF Fire
This default is not effective until software version 1.16