Specifications – Grain Systems PNEG-1702 User Manual
Page 31

5. Specifications
PNEG-1702 ETL Listed GSI/FFI Portable Dryer Manual
31
1200 Series Dryer Specifications
1200S Series Dryer Specifications
1214
1216
1218
1220
1222
1226
Total Holding Capacity (Bushels)
381
436
490
544
599
708
Grain Column Holding
Capacity (Bushels)
329
376
423
470
517
611
Fan
26'' 10-13 HP
36'' 10-13 HP
26'' 10-13 HP
36'' 15 HP
26'' 10-13 HP
36'' 15 HP
28'' 10-13 HP
40" 15 HP
28'' 10-13 HP
42'' 20 HP
28'' 10-13 HP
42'' 25 HP
Top Auger
8'' Dia.
5 HP
8'' Dia.
5 HP
8'' Dia.
5 HP
8'' Dia.
7-1/2 HP
8'' Dia.
7-1/2 HP
8'' Dia.
10 HP
Capacity (BHP)
3800
3800
3800
3800
3800
3800
Bottom Auger
8'' Dia.
5 HP
8'' Dia.
5 HP
8'' Dia.
5 HP
8'' Dia.
7-1/2 HP
8'' Dia.
7-1/2 HP
8'' Dia.
10 HP
Meter Roll Drive
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
Capacity - Maximum Rate
1
(BHP)
1960
2240
2520
2800
3080
3640
Electrical Load (Fans, Top and Bottom Augers
2
)
1 Phase, 220 Volt
142
156
156
172
-
-
3 Phase, 220 Volt
92
99
99
112
126
150
3 Phase, 440 Volt
47
50
50
57
63
75
3 Phase, 575 Volt
37
42
42
47
52
61
3 Phase, 380 Volt
50
61
61
70
75
90
1
Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate.
2
Excludes auxiliary load and unload conveyor equipment.
1214S
1218S
1220S
1222S
1226S
Total Holding Capacity (Bushels)
381
490
544
599
708
Grain Column Holding Capacity (Bushels)
329
423
470
517
611
Fan
28'' 10-13 HP
(2)
36'' 10-13 HP
(2)
36'' 15 HP
(2)
36'' 15 HP
(2)
40'' 25 HP
(2)
Top Auger
8'' Dia.
5 HP
8'' Dia.
5 HP
8'' Dia.
7-1/2 HP
8'' Dia.
7-1/2 HP
8'' Dia.
10 HP
Capacity (BHP)
3800
3800
3800
3800
3800
Bottom Auger
8'' Dia.
5 HP
8'' Dia.
5 HP
8'' Dia.
7-1/2 HP
8'' Dia.
7-1/2 HP
8'' Dia.
10 HP
Meter Roll Drive
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
Capacity - Maximum Rate
1
(BHP)
1960
2520
2800
3080
3640
Electrical Load (Fans, Top and Bottom Augers
2
)
1 Phase, 220 Volt
142
142
186
186
-
3 Phase, 220 Volt
93
93
118
118
180
3 Phase, 440 Volt
47
47
60
60
90
3 Phase, 575 Volt
40
33
48
48
72
3 Phase, 380 Volt
50
50
80
80
115
1
Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate.
2
Excludes auxiliary load and unload conveyor equipment.