Installation – Grain Systems PNEG-1702 User Manual
Page 21

4. Installation
PNEG-1702 ETL Listed GSI/FFI Portable Dryer Manual
21
Fuel System Specifications and Recommendations (NG) Natural Gas
Dryer
Model #
Maximum Heat
Capacity BTU Per Hour
Maximum Fuel Flow
Cubic Feet Per Hour
Fuel Line Size*
Heater Orifice Drill Size
108/1108/190
3,500,000
3500
1-1/2''
3/8"
112/1112/270
4,500,000
4500
1-1/2'' 1/2"
114/1114/320
5,750,000
5750
1-1/2''
33/64"
116/1116/370
5,750,000
5750
1-1/2'' 33/64"
118/1118/400
7,000,000
7000
2''
35/64"
120/1120/460
7,500,000
7500
2'' 37/64"
122/1122/511
8,500,000
8500
2''
19/32"
126/1126/601
9,500,000
9500
2'' 41/64"
1214/2120
5,800,000
5800
1-1/2''
(U)13/32" (L)5/16"
1216
6,800,000
6800
2'' (U)1/2"
(L)5/16"
1218/2125
6,800,000
6800
2''
(U)1/2" (L)5/16"
1220/2130
8,750,000
8750
2'' (U)33/64"
(L)5/16"
1222
10,000,000
10000
2''
(U)35/64" (L)5/16"
1226/2140
10,500,000
10500
2'' (U)37/64"
(L)5/16"
1214S/2141
7,000,000
7000
1-1/2''
(2)-13/32"
1218S/2181
9,000,000
9000
1-1/2'' (2)-1/2"
1220S/500H
11,500,000
11500
2''
(2)-33/64"
1222S/2221
14,000,000
14000
2'' (2)-35/64"
1226S/650M
15,000,000
15000
2''
(2)-37/64"
2314/3142
11,750,000
11750
2''
Top-33/64" Base (2)-3/8"
2318/3182
14,000,000
14000
2''
Top-35/64" Base (2)-13/32"
2320/3202
16,500,000
16500
3''
Top-37/64" Base (2)-1/2"
2322/3222
17,500,000
17500
3''
Top-19/32" Base (2)-1/2"
2326/3262
24,500,000
24500
3''
Top-41/64" Base (2)-17/32"
2420/1000H
18,000,000
18000
3''
(4)-1/2"
2426/1300M
26,000,000
26000
3'' (4)-17/32"
3414/4143
17,500,000
17500
3''
Top-33/64" Mid-33/64" Base (2)-3/8"
3418/4183
21,000,000
21000
3''
Top-35/64" Mid-35/64" Base (2)-13/32"
3420/4203
24,000,000
24000
3''
Top-37/64" Mid-37/64" Base (2)-1/2"
3422/4223
26,000,000
26000
3''
Top-19/32" Mid-19/32" Base (2)-1/2"
3426/4263
32,000,000
32000
3''
Top-41/64" Mid-41/64" Base (2)-17/32"
3620/1500H
27,000,000
27000
3'' (6)-1/2"
3626/2000M
39,000,000
39000
3''
(6)-17/32"
* The minimum size of the fuel line for distances of 30.48 m (100').