Grain Systems PNEG-1928 User Manual
Instructions

Date: 06-27-13
PNEG-1928
Instructions
1004 East Illinois Street • Assumption, IL 62510 • 1-217-226-4421
PNEG-1928
Printed in the U.S.A.
Copyright © 2013 by GSI Group
www.gsiag.com
Page 1 of 9
CN-305799
UV Sensor Retrofit Instruction
Manual for Portable Dryers
Tools you will need for this installation:
Figure 1
Parts included with the UV-SENSE-KIT:
Part #
Description
PNEG-1928
Installation Instructions (This Document)
D03-1168
UV Flame Sensor Relay
HF-7621
UV Flame Sensor Cable
GT3-1182
Time Delay Relay
GT3-1181
Time Delay Relay Base
FH-1310
Heyco Cord Connector
FH-1309
Lock Nut for Cord Connector
THH-4129
1/2" x 5" Nipple
D67-0005
1/2" Coupler
007-1149-9
1/2" to 1/8" Reducer Bushing
406-2293-8
Din Rail 3" Long
S-2786
Two (2) Self-Tapping Screws used to Mount Din Rail
Portable drill
Phillips bit
9/64" Drill bit
7/8" Hole saw or step bit
1/8" Tip screwdriver