PNEG-1707 TM-Series Tower Dryer
Lubrication Table
Location
Instructions
Type of
Lubrication
Lubrication Interval
Accutrol (sweep unload)
bottom shaft bearing.
Lubricate slowly until lube
shows through seal.
Wipe clean.
High quality, grade #2
lithium based grease.
Beginning of season (annually).
Blower motor bearings.
See motor lubrication
procedure
.
High quality, grade #2
lithium based grease.
Every 2 years (Normal
operation, ever 8-10 months
continuous operation).
Metering variable speed
drive motor.
See motor lubrication
procedure
.
High quality, grade #2
lithium based grease.
Every 2 years (Normal
operation, ever 8-10 months
continuous operation).
Accutrol sweep gearbox.
Grease filled gearbox.
Additional grease does not
need to be added.
¹Lubrication of motors - Operate motor for 20 minutes. Clean grease fitting. Remove grease relief plug and using a
low pressure grease gun, pump in the required grease. After re-lubricating, allow motor to run for 10 minutes before
replacing relief hardware. DO NOT over grease.