Static

Fan Model

Pressure

60

80

100

120

140

160

180

2"

2

2

4

5

7

8

10

20HP

4"

1

2

3

4

5

7

8

6"

1

2

3

4

5

6

7

2"

2

3

5

7

9

12

15

25HP

4"

2

3

4

6

8

10

13

6"

2

2

4

5

6

8

10

2"

2

4

6

8

11

15

30HP

4"

2

4

5

7

10

13

6"

2

3

4

6

8

10

13

2"

3

6

8

12

40HP

4"

3

5

7

11

14

6"

3

4

7

9

12

Gauge Pressure (Psi) Required To Maintain Temperature ( Approximate )

( 20-40 Horsepower High Temp Propane Units Only )

Heat Rise Degrees F

Static

Fan Model

Pressure

60

80

100

120

140

160

180

2"

0.75

1.25

1.75

2.5

3.25

4.25

5.5

20HP

4"

0.5

1

1.5

2

2.75

3.5

4.5

6"

0.5

0.75

1.25

1.75

2.25

3

3.75

2"

1

1.75

2.25

3.5

4.75

6.25

25HP

4"

0.75

1.5

2.25

3.25

4

5.25

6.25

6"

0.5

1.25

1.75

2.5

3.25

4.25

5.5

2"

1.25

2

3

4.5

6

30HP

4"

1

1.75

2.75

3.75

5

7

6"

0.75

1.5

2.25

3

4

5.25

7

2"

1.75

3

4.5

6.25

40HP

4"

1.5

2.5

4

5.5

6"

1.25

2.25

3.5

4.75

6.75

( 20-40 Horsepower High Temp Natural Gas Units Only )

Heat Rise Degrees F

Gauge Pressure (Psi) Required To Maintain Temperature ( Approximate )

HIGH TEMPERATURE 20-40hp 5/16" orifice

OPERATING PRESSURE (PSI)

2

4

6

8

10

12

14

15

ALL
MODELS

1663135

2345140

2878779

3328663

3721115

4068100

4393548

4541914

BTU’s Per Gauge Pressure (PSI) PROPANE MODELS (Approximate)

1

2

3

4

5

6

7

ALL
MODELS

1597824

2266320

2770656

3195648

3573216

3919776

4234416

BTU’s Per Gauge Pressure (PSI) NATURAL GAS MODELS (Approximate)

HIGH TEMPERATURE 20-40hp 15/32” orifice

OPERATING PRESSURE (PSI)

HEATER OPOERATION PROCEDURE