10. Electrical Load Information
30
PNEG-338 Portable Dryer Installation and Towing
400AB
1 PH 230V
Top Auger
5
26
231
130
350
100
Bottom Auger
5
26
100
Fan
10 to 17
78
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
5
13.2
145
65.4
200
60
Bottom Auger
5
13.2
60
Fan
15
39
60
(2) Auxiliary
(2) 10
52
*
3 PH 440V
Top Auger
5
6.6
78
32.7
150
60
Bottom Auger
5
6.6
60
Fan
15
19.5
60
(2) Auxiliary
(2) 10
26
*
415AB
1 PH 230V
Top Auger
5
26
252
148
350
100
Bottom Auger
5
26
100
Fan
(2) 10 to 12
96
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
5
13.2
165
82.4
225
60
Bottom Auger
5
13.2
60
Fan
(2) 10
56
60
(2) Auxiliary
(2) 10
52
*
3 PH 440V
Top Auger
5
6.6
82
41.2
150
60
Bottom Auger
5
6.6
60
Fan
(2) 10
28
60
(2) Auxiliary
(2) 10
26
*
600AB
1 PH 230V
Top Auger
7.5
31
332
218
400
100
Bottom Auger
7.5
31
100
Fan
(2) 10 to 17
156
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
7.5
20
235
118
300
90
Bottom Auger
7.5
20
90
Fan
(2) 15
78
60
(2) Auxiliary
(2)15
78
*
3 PH 440V
Top Auger
7.5
10
123
59
200
60
Bottom Auger
7.5
10
60
Fan
(2) 15
39
60
(2) Auxiliary
(2) 15
39
*
*Auxiliaries run through load and unload breakers.
Dryer
Model #
Voltage
Motor
HP
Fuel Load
Amps
Maximum Amps
with Auxiliaries
Minimum
Amps
Recommended
Service in Amps
Branch Breaker
in Amps