beautypg.com

Electrical load information – Grain Systems PNEG-338 User Manual

Page 24

background image

10. Electrical Load Information

24

PNEG-338 Portable Dryer Installation and Towing

1114

1 PH 230V

Top Auger

5

26

231

130

350

100

Bottom Auger

5

26

100

Fan

10 to 17

78

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Top Auger

5

13.2

145

65.4

200

60

Bottom Auger

5

13.2

60

Fan

15

39

60

(2) Auxiliary

(2) 10

52

*

3 PH 440V

Top Auger

5

6.6

78

32.7

150

60

Bottom Auger

5

6.6

60

Fan

15

19.5

60

(2) Auxiliary

(2) 10

26

*

1116

1 PH 230V

Top Auger

5

26

231

130

350

100

Bottom Auger

5

26

100

Fan

10 to 17

78

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Top Auger

5

13.2

145

65.4

200

60

Bottom Auger

5

13.2

60

Fan

15

39

60

(2) Auxiliary

(2) 10

52

*

3 PH 440V

Top Auger

5

6.6

78

32.7

150

60

Bottom Auger

5

6.6

60

Fan

15

19.5

60

(2) Auxiliary

(2) 10

26

*

1118

3 PH 220V

Top Auger

5

13.2

158

76.4

250

60

Bottom Auger

5

13.2

60

Fan

20

50

90

(2) Auxiliary

(2) 10

52

*

3 PH 440V

Top Auger

5

6.6

84

38.2

150

60

Bottom Auger

5

6.6

60

Fan

20

25

60

(2) Auxiliary

(2) 10

26

*

1120

3 PH 220V

Top Auger

7.5

20

219

104

300

90

Bottom Auger

7.5

20

90

Fan

25

64

90

(2) Auxiliary

(2) 15

78

*

3 PH 440V

Top Auger

7.5

10

115

52

200

60

Bottom Auger

7.5

10

60

Fan

25

32

60

(2) Auxiliary

(2) 15

39

*

1122

3 PH 220V

Top Auger

7.5

20

231

114

300

90

Bottom Auger

7.5

20

90

Fan

30

74

90

(2) Auxiliary

(2) 15

78

*

3 PH 440V

Top Auger

7.5

10

120

57

200

60

Bottom Auger

7.5

10

60

Fan

30

37

60

(2) Auxiliary

(2) 15

39

*

*Auxiliaries run through load and unload breakers.

Dryer

Model #

Voltage

Motor

HP

Fuel Load

Amps

Maximum Amps

with Auxiliaries

Minimum

Amps

Recommended

Service in Amps

Branch Breaker

in Amps