Electrical load information – Grain Systems PNEG-338 User Manual
Page 25

10. Electrical Load Information
PNEG-338 Portable Dryer Installation and Towing
25
1126
3 PH 220V
Top Auger
10
26
277
154
400
90
Bottom Auger
10
26
90
Fan
40
102
125
(2) Auxiliary
(2) 15
78
*
3 PH 440V
Top Auger
10
13
143
77
250
60
Bottom Auger
10
13
60
Fan
40
51
90
(2) Auxiliary
(2) 15
39l
*
1214
1 PH 230V
Top Auger
5
26
252
148
300
100
Bottom Auger
5
26
100
Top Fan
10 to 12
48
100
Bottom Fan
10 to 12
48
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
5
13.2
170
87.4
225
60
Bottom Auger
5
13.2
60
Top Fan
10
28
60
Bottom Fan
10 to 12
33
60
(2) Auxiliary
(2) 10
52
*
3 PH 440V
Top Auger
5
6.6
90
43.7
150
60
Bottom Auger
5
6.6
60
Top Fan
10
14
60
Bottom Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 10
26
*
1216
1 PH 230V
Top Auger
5
26
286
178
400
100
Bottom Auger
5
26
100
Top Fan
10 to 17
78
100
Bottom Fan
10 to 12
48
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
5
13.2
183
98.4
225
60
Bottom Auger
5
13.2
60
Top Fan
15
39
60
Bottom Fan
10 to 12
33
60
(2) Auxiliary
(2) 10
52
*
3 PH 440V
Top Auger
5
6.6
60
Bottom Auger
5
6.6
96
49.2
150
60
Top Fan
15
19.5
60
Bottom Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 10
26
*
*Auxiliaries run through load and unload breakers.
Dryer
Model #
Voltage
Motor
HP
Fuel Load
Amps
Maximum Amps
with Auxiliaries
Minimum
Amps
Recommended
Service in Amps
Branch Breaker
in Amps