beautypg.com

Milton CAT G40LG 40kw_50kVA Spec Sheet User Manual

Page 2

background image

ENGINE SPECIFICATIONS

General

Cooling System

Make

Generac

Cooling System Type

Pressurized Closed

EPA Emissions Compliance

Stationary Emergency

Water Pump Flow

38 gal/min

EPA Emissions Engine Reference

See Emissions Data Sheet

Fan Type

Pusher

Cylinder #

8

Fan Speed (rpm)

2143

Type

V

Fan Diameter mm (in.)

508 (20)

Displacement - L

5.4

Coolant Heater Wattage

1500

Bore - mm (in.)

90.17 (3.55)

Coolant Heater Standard Voltage

120V

Stroke - mm (in.)

105.92 (4.17)

Compression Ratio

9:1

Intake Air Method

Naturally Aspirated

Number of Main Bearings

4

Fuel System

Connecting Rods

Forged

Fuel Type

Natural Gas, Propane Vapor

Cylinder Head

Aluminum

Carburetor

Down Draft

Cylinder Liners

No

Secondary Fuel Regulator

Standard

Ignition

Single Fire

Fuel Shut Off Solenoid

Standard

Pistons

Aluminum Alloy

Operating Fuel Pressure

8" - 14" H2O*

Crankshaft

Nodular Iron

Lifter Type

Hydraulic

*Fuel pressure must remain within specified range and not drop more than 1
in. w.c. from static (no-load) to full load.

Intake Valve Material

Steel Alloy

Exhaust Valve Material

Hardened Steel

Hardened Valve Seats

Yes

Engine Electrical System
System Voltage

12VDC

Lubrication System

Battery Charging Alternator (Amps)

30

Oil Pump Type

Gear

Battery Size (at 0ºC)

525/700/925CCA

Oil Filter Type

Full-flow spin-on cartridge

Battery Group

24/27/31

Crankcase Capacity - L (qts)

5.7 (6)

Battery Voltage

12VDC

Ground Polarity

Negative

ALTERNATOR SPECIFICATIONS

Standard Model

390

Voltage Regulator Type

Full Digital

Poles

4

Number of Sensed Phases

3

Field Type

Revolving

Regulation Accuracy (Steady State)

+/- 0.25%

Insulation Class - Rotor

H

Insulation Class - Stator

H

Total Harmonic Distortion

<5%

Engine Governing

Telephone Interference Factor (TIF)

<50

Governor

Electronic

Standard Excitation

Brushless

Frequency Regulation (Steady State)

+/- 0.25%

Bearings

Sealed Ball

Coupling

Flexibile Disc

Load Capacity - Standby

40kW

Prototype Short Circuit Test

Yes

CODES AND STANDARDS COMPLIANCE (WHERE APPLICABLE)

NFPA 99

BS5514

NFPA 110

SAE J1349

ISO 8528-5

DIN6271

ISO 1708A.5

IEEE C62.41 TESTING

ISO 3046

NEMA ICS 1
UL2200

2 of 5

G40LG

application and engineering data

G40LG 40kW