beautypg.com

Olympian electronic governors gas engines, Regulation .....................isochronous, Steady state regulation ........±0.25 – Milton CAT G200LG4 200kW_250kVA Electronic Governor User Manual

Page 2: Factory installed and adjusted, Fully adjustable via genlink, Low-speed exercise capability, Fast response, High reliability, No maintenance required

background image

Olympian Electronic Governors

Gas Engines

Regulation .....................Isochronous

Steady State Regulation ........±0.25%

Olympian Electronic governor system is

standard on gas gensets with Olympian’s

Digital Control Platform (H panel)
control system

Factory installed and adjusted

Fully adjustable via Genlink®

Low-speed exercise capability

Fast response

High reliability

No maintenance required

ACTUATOR

DESCRIPTION:
Die Cast enclosure housing the throttle plate and the gear-driven rotary actuator. The interior components are sealed
against dust, dirt and moisture. The gear drive is directly connected to the throttle plate. Spring return to idle on loss of
power.
MANUFACTURER ............................................................Olympian
DESIGN ............................................................................ Bosch
TYPE ................................................................................ Motor Driven Throttle Plate
OPERATING VOLTAGE .................................................... 12/24vdc
RESPONSE TIME ............................................................ < 30ms
TORQUE .......................................................................... > 0.7 Ft. Lbs
OUTPUT ........................................................................... Rotary (internal – no linkage)

CONTROLLER

DESCRIPTION:
Governor driver module located in the genset control panel. Sealed unit with waterproof connections. DCP
software-controlled speed governing, fully adjustable via Genlink

®

.

The Olympian electronic governor system applies to the following gas gensets with Olympian’s Digital Control Platform
(H panel) control system:

2.4L 25kW ........................................................................ STANDARD
4.2L 35 – 45kW ................................................................ STANDARD
5.4L 45 – 80kW ................................................................ STANDARD
6.8L 70 – 150kW .............................................................. STANDARD
13.3L 135 – 300kW .......................................................... STANDARD

Printed in USA 11.07

Data subject to change without notice.

Information contained in this publication may be considered confidential. Discretion is recommended when distributing.

Materials and specifications are subject to change without notice.

CAT, CATERPILLAR, OLYMPIAN, their respective logos, and “Caterpillar Yellow,” as well as

corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.