beautypg.com

Milton CAT G70LG 70kW_88kVA Attenuated Enclosure Sound Data User Manual

Sound test results, Genset: enclosure, G70lg 6.8l sound attenuated enclosure

background image

Genset:

Enclosure:

Right

Left

Notes:

1. All positions 23 ft (7M) from side faces of generator set.
2. Generator operating at full load.
3. Test conducted on a 100 foot diameter asphault surface.
4. Non-enclosed sets do not include exhaust sound during testing.

Sound Test Results

G70LG 6.8L

Sound Attenuated Enclosure

Front

Back

Measured Sound Levels - 60 Hz

72.7

71.6

78.0

74.0

60

62

64

66

68

70

72

74

76

78

80

82

84

86

88

90

92

94

96

1

2

3

4

Position Number

dB

(A

) @ 7 Meter

s

Actual

Average

Avg. 74.1 dBA

RADIATOR END

GENERATOR END

Pos 1

Pos 2

Pos 3

Pos 4

DATA SUBJECT TO CHANGE WITHOUT NOTICE