beautypg.com

Milton CAT G60LG 60kW_75kVA Weather Protective Enclosure Sound Data User Manual

Sound test results, Genset: enclosure, G60lg 6.8l weather protected enclosure

background image

Genset:

Enclosure:

Right

Left

Notes:

1. All positions 23 ft (7M) from side faces of generator set.
2. Generator operating at full load.
3. Test conducted on a 100 foot diameter asphault surface.
4. Non-enclosed sets do not include exhaust sound during testing.

Sound Test Results

G60LG 6.8L

Weather Protected Enclosure

Front

Back

Measured Sound Levels - 60 Hz

77.5

75.9

78.3

78.3

66

68

70

72

74

76

78

80

82

84

86

88

90

1

2

3

4

Position Number

dB

(A

) @ 7 Meter

s

Actual

Average

Avg. 77.5 dBA

RADIATOR END

GENERATOR END

Pos 1

Pos 2

Pos 3

Pos 4

DATA SUBJECT TO CHANGE WITHOUT NOTICE

0187480SSD rev A 03/10