EMISSIONS DATA

EPA TIER-3 2005 - ---- *************************************************** D7
Gaseous emissions data measurements are consistent with those described
in 40 CFR, EU 97/68/EC, ECE Regulation No. 96 and ISO 8178 for measuring
HC, CO, PM, and NOx.

Gaseous emissions values are WEIGHTED CYCLE AVERAGES and are in compliance
with the following non-road regulations:

LOCALITY AGENCY/LEVEL MAX LIMITS - g/kW-hr
------------------ ------------ -----------------------------------
U. S. (incl Calif) EPA/TIER-3 CO:3.5 NOx + HC:4.0 PM:0.2

REFERENCE EXHAUST STACK DIAMETER

--

WET EXHAUST MASS

6,241.3 LB/HR

WET EXHAUST FLOW (908.60 F STACK TEMP )

3,658.60 CFM

WET EXHAUST FLOW RATE ( 32 DEG F AND 29.98 IN HG )

1,291.00 STD CFM

DRY EXHAUST FLOW RATE ( 32 DEG F AND 29.98 IN HG )

1,182.69 STD CFM

FUEL FLOW RATE

32 GAL/HR