beautypg.com

Milton CAT G80LG4-2 80kW_100kVA Spec Sheet User Manual

Page 2

background image

ENGINE SPECIFICATIONS

General

Cooling System

Make

Generac

Cooling System Type

Pressurized Closed

EPA Emissions Compliance

Stationary Emergency

Water Pump Flow

26 gal/min

EPA Emissions Engine Reference

See Emissions Data Sheet

Fan Type

Pusher

Cylinder #

8

Fan Speed (rpm)

2330

Type

V

Fan Diameter mm (in.)

558 (22)

Displacement - L (Cu. In.)

8.9L (540)

Coolant Heater Wattage

1500W

Bore - mm (in.)

114.31 (4.5)

Coolant Heater Standard Voltage

120V

Stroke - mm (in.)

107.15 (4.25)

Compression Ratio

10.5:1

Intake Air Method

Naturally Aspirated

Number of Main Bearings

5

Fuel System

Connecting Rods

Forged

Fuel Type

Natural Gas, Propane

Cylinder Head

Cast Iron

Carburetor

Down Draft

Cylinder Liners

No

Secondary Fuel Regulator

Standard

Ignition

High Energy

Fuel Shut Off Solenoid

Standard

Pistons

Aluminum Alloy

Operating Fuel Pressure

11" - 14" H2O

Crankshaft

Steel

Lifter Type

Hydraulic Roller

Intake Valve Material

Steel Alloy

Exhaust Valve Material

Stainless Steel

Engine Electrical System

Hardened Valve Seats

Yes

System Voltage

12VDC

Battery Charging Alternator (Amps)

30

Lubrication System

Battery Size

925CCA

Oil Pump Type

Gear

Battery Group

31

Oil Filter Type

Full-flow spin-on cartridge

Battery Voltage

12VDC

Crankcase Capacity - L (qts)

8.0 (8.5)

Ground Polarity

Negative

ALTERNATOR SPECIFICATIONS

Standard Model

390mm

Voltage Regulator Type

Full Digital

Poles

4

Number of Sensed Phases

3

Field Type

Revolving

Regulation Accuracy (Steady State)

+/- 1.0%

Insulation Class - Rotor

H

Insulation Class - Stator

H

Total Harmonic Distortion

<5%

Engine Governing

Telephone Interference Factor (TIF)

<50

Governor

Electronic

Standard Excitation

Brushless

Frequency Regulation (Steady State)

+/- 0.25%

Bearings

Sealed Ball

Coupling

Direct Drive

Load Capacity - Standby

100%

Prototype Short Circuit Test

Yes

CODES AND STANDARDS COMPLIANCE (WHERE APPLICABLE)

NFPA 99

BS5514

NFPA 110

SAE J1349

ISO 8528-5

DIN6271

ISO 1708A.5

IEEE C62.41 TESTING

ISO 3046

NEMA ICS 1

UL2200

2 of 5

Rating Definitions:
Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%)
Prime – Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. (Max. load factor = 80%) A 10% overload capacity is available for 1 out of every
12 hours.

G80LG

application and engineering data

G80LG 80kW