Ul listed sub-assembly installation instructions, Acm4cb, Screw – Altronix ACM4E Installation Instructions User Manual
Page 8: Stand-off stud, Enclosure, Member, Sub-assembly, 8 - acm4 series, Divider, Sub-assembly mounting holes

- 8 -
ACM4 series
UL Listed Sub-Assembly Installation Instructions:
The following Altronix sub-assembly modules may be field installed in the AL300ULX(R), AL600ULX(R),
AL400ULX(R) power supply/chargers: ACM4 or ACM4CB
1. Disconnect power before proceeding with sub-assembly installation.
2. Fasten stand-offs (supplied) to the corresponding studs in the enclosure.
3. Align mounting holes of sub-assembly with stand-offs (Fig. 8, pg. 8).
Refer below for the location and position for placement of sub-assembly.
4. Fasten sub-assembly to enclosure using the four (4) screws (supplied) (Fig. 9, pg. 8).
5. Connect red and black power leads of CM type jacketed wire (supplied), as shown below:
N
C
C
N
O
C
O
M
O
U
T
P
U
T
1
N
C
C
N
O
C
O
M
O
U
T
P
U
T
2
N
O
C
NC
FA
CP
- --
+
- --
+
Po
we
r
Co
ntr
ol
+ I
NP
---
T
+ R
ET
---
IN
TE
RFA
CE
LE
D
1
S
W
1
S
W
2
S
W
3
S
W
4
LE
D
2
LE
D
3
LE
D
4
1
0
A
3
A
3
A
3
A
3
A
T
R
IG
G
E
R
IN
P
U
T
T
R
G
N
C
C
N
O
C
O
M
O
U
T
P
U
T
3
N
C
C
N
O
C
O
M
O
U
T
P
U
T
4
J2
J1
J3
IN
G
N
D
2
IN
G
N
D
1
IN
G
N
D
3
IN
G
N
D
4
--- DC
+
L
G
N
N
C
C
N
O
N
C
C
N
O
+
BAT ---
A
C
F
A
IL
B
A
T
F
A
IL
Sub-Assembly
Mounting
Holes
Divider
Red Lead
Black Lead
Power Supply Board for:
AL300ULX(R)
AL400ULX(R)
AL600ULX(R)
- --
+
- --
+
Po
we
r
Co
ntr
ol
Keep power limited wiring separate
from non-power limited.
Use minimum .25" spacing.
ACM4
Fig. 9
Enclosure Dimensions:
13.5”H x 13”W x 3.25”D
Mounting Position for
UL Listed Sub-Assembly Installation.
Screw
Sub-Assembly
Stand-off
Stud
Enclosure
Fig. 8
Terminals
Power Leads
Power Supply
Sub-Assembly
(provided)
Output
Input
Red Lead
DC +
Control +
Black Lead
DC --
Control --
N
C
C
N
O
C
O
M
O
U
T
P
U
T
1
N
C
C
N
O
C
O
M
O
U
T
P
U
T
2
N
O
C
NC
FA
CP
- --
+
- --
+
Po
we
r
Co
ntr
ol
+ I
NP
---
T
+ R
ET
---
IN
TE
RFA
CE
LE
D
1
S
W
1
S
W
2
S
W
3
S
W
4
LE
D
2
LE
D
3
LE
D
4
T
R
IG
G
E
R
IN
P
U
T
T
R
G
N
C
C
N
O
C
O
M
O
U
T
P
U
T
3
N
C
C
N
O
C
O
M
O
U
T
P
U
T
4
J2
J1
J3
IN
G
N
D
2
IN
G
N
D
1
IN
G
N
D
3
IN
G
N
D
4
1
0
A
ACM4CB
Altronix is not responsible for any typographical errors.
Altronix Corp.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
IIACM4/ series
J09H
MEMBER