beautypg.com

Altronix ACM4E Installation Instructions User Manual

Page 2

background image

- 2 -

ACM4 series

Overview:

These units convert one (1) 12 to 24 volt AC or DC input into four (4) independently controlled fused or PTC protected
outputs. These power outputs can be converted to dry form “C” contacts (ACM4/ACM4E only). Outputs are activated by
an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push
Button, PIR, etc. The units will route power to a variety of access control hardware devices including Mag Locks, Electric
Strikes, Magnetic Door Holders, etc. All interconnecting devices must be UL Listed. Outputs will operate in both Fail-Safe
and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for
both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for
board operation and the other for lock/accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring,
or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all
of the four (4) outputs.

Configuration Reference Chart:

*Install in Altronix Power Supply/Chargers AL300ULX, AL400ULX and AL600ULX only. Total output current when

ACM4/ACM4CB is utilized as a sub-assembly with power supply/chargers listed below (see Total Output Chart, below).

Note: The total for all outputs combined is not to exceed 8 amp for ACM4CBE and 10 amp for

ACM4E.

Total Output Chart:

Note: ACM4/ACM4CB can only be utilized with the power supplies listed above.

Specifications:

• 12 to 24volt AC or DC operation (setting not required).
• Input Ratings (ACM4/ACM4CB only):

- 12VDC @ .4 amp or 24VDC @ .2 amp.

Input Ratings (ACM4E/ACM4CBE only):

- 12VDC @ .4 amp or 24VDC @ .2 amp.
- 12VAC @ .4 amp or 24VAC @ .3 amp.

• Power supply input options:

a) One (1) common power input (board and lock power).
b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/hardware power).

• Four (4) Access Control System trigger inputs:

a) Four (4) normally open (NO) inputs.
b) Four (4) open collector sink inputs.
c) Any combination of the above.

• Four (4) independently controlled outputs:

a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
b) Four (4) dry form “C” 5 amp rated relay outputs (ACM4/ACM4E only).
c) Any combination of the above (ACM4/ACM4E only).

• Four (4) auxiliary power outputs (unswitched).

Altronix
Model
Number

ACM4

4

x

----

3 amp

-

*

UL File # BP6714

UL Listed for Access Control

System Units (UL 294).

“Signal Equipment” Evaluated to

CSA Standard C22.2

No.205-M1983

ACM4E

4

x

----

3 amp

-

x

ACM4CB

4

----

x

2 amp

x

*

ACM4CBE

4

----

x

2 amp

x

x

Number of

OutputsFuse Protected

Outputs PTC Protected

Outputs Output Ratings

(per output)

Enclosure Agenc

y Listings

UL Listings and

File Numbers

Class 2 Rated P

ow

er

Limited Outputs

UL Listed
Sub-Assembly.

UL Listed
Accessory.

UL Listed
Sub-Assembly.

UL Listed
Accessory.

Power Supply

12 volt DC Output

24 volt DC Output

AL300ULX

2.1 amp

2.3 amp

AL400ULX

2.8 amp

3.6 amp

AL600ULX

5.6 amp

5.8 amp