Altronix AL600ULMR Installation Instructions User Manual
Page 2
- 2 -
M series
Overview:
These multi-output access control power supply/chargers are specifically designed for use with access control systems and
accessories. These units convert a 115VAC, 60Hz input into five (5) individually protected 12VDC or 24VDC outputs (see
specifications). Each output will route power to a variety of access control hardware devices including Mag Locks, Electric
Strikes, Magnetic Door Holders, etc. These outputs will operate in both Fail-Safe and Fail-Secure modes. Controlled
trigger input is achieved through normally open [NO] or normally closed [NC] supervised input or the polarity reversal
from an FACP (Fire Alarm Control Panel). A form “C” dry output relay enables HVAC Shutdown, Elevator Recall or may
be used to trigger auxiliary devices.
M Series Power Supply Configuration Reference Chart:
Altronix
Model
Number
12VDC Total Output Current
(amp)
24VDC Total Output Current
(amp)
Outputs
Class 2 Rated Power Limited
115VAC 60Hz Input (current draw/amp)
Individual Output Rating (amp)
Power Supply Board Input Fuse Rating
Power Supply Board Output Fuse Rating
Agency Listings
UL Listings and
File Numbers
AL300ULM
2.5
2.5
5 Yes 3.5 amp
2
5A/
250V
15A/
32V
UL 294
UL Listed Access Control System Unit.
UL 603
UL Listed for Burglar Alarms Systems.
UL 1069
UL Listed Hospital Signaling and
Nurse Call Equipment.
UL 1481
UL Listed for Power Supplies for
Fire Protective Signaling Systems
AL400ULM
4
3
5 Yes 3.5 amp
2
5A/
250V
15A/
32V
AL600ULM
6
6
5 Yes 3.5 amp
2
5A/
250V -------------
AL1012ULM
10
------------ 5 Yes 2.6 amp
2
5A/
250V
15A/
32V
UL File # BP617
UL 294
UL Listed Access Control System Unit.
AL1024ULM ------------
10
5 Yes 4.2 amp
2
5A/
250V
15A/
32V
UL 294
UL Listed Access Control System Unit.
UL 1481
UL Listed for Power Supplies for
Fire Protective Signaling Systems
Specifications:
Input:
• Power input 115VAC 60Hz (see reference chart above).
• Fire Alarm Panel or Access Control System trigger
inputs. [NO] or [NC] supervised trigger input and
polarity reversal trigger input (4mA draw from FACP).
Output:
• Five (5) individual power limited class 2 outputs.
• Current limit is 2 amp @ 12VDC or 24VDC
per output (12VDC only for AL1012ULM,
24VDC only for AL1024ULM).
Burglar Alarm Applications (UL 603)
AL300ULM and AL400ULM only:
12VDC = 10VDC-13.2VDC.
24VDC = 20VDC-26.4VDC.
• Filtered and electronically regulated outputs.
• Thermal and short circuit protection with auto reset.
• Overload protection.
• Output relay energizes when unit is triggered
(form “C” contact rated 1 amp @ 28VDC).
Battery Backup:
• Built-in charger for sealed lead acid or gel type batteries.
• Automatic switch over to stand-by battery when AC fails.
Battery Backup (cont’d):
• Zero voltage drop when switching over to
battery backup.
• AL300ULM, AL400ULM, AL600ULM and
AL1012ULM (Power Supply Board) maximum
charge current 0.7 amp.
AL1024ULM (Power Supply Board) maximum
charge current 3.6 amp.
• AL300ULM, AL400ULM and AL600ULM enclosures
accommodate up to two (2) 12VDC/7AH batteries.
• AL1012ULM should be fitted with
one (1) 12VDC/12AH battery.
• AL1024ULM should be fitted with
two (2) 12VDC/12AH batteries.
Visual Indicators:
• DC output LED indicator.
• LEDs indicate condition of power outputs.
• Power & input trigger LED’s.
Supervision:
• AC fail supervision (form “C” contact).
• Low battery supervision (form “C” contact).
• Battery presence supervision (form “C” contact).