Maximum Length of Coax Type vs. Camera Power/PoE Class:

Camera Power/

PoE Class

RG59/U

(23AWG)

RG59/U

(22AWG)

RG59/U

(20AWG)

RG59/U

(18AWG)

RG6/U

(18AWG)

Max. Length (ft./meters)

13W/0 or 13W/3

855’/260.64m

1,100’/335.28m

1,500’+/457.20m+ 1,500’+/457.20m+ 1,500’+/457.20m+

25W

390’/260.64m

494’/335.28m

785’/457.20m+

1,200’/457.20m+

1,200’/457.20m+

60W

10’+/10m+

10’+/10m+

10’+/10m+

10’+/10m+

10’+/10m+

90W

10’+/10m

10’+/10m

10’+/10m+

10’+/10m+

10’+/10m+

120W

10’+/10m

10’+/10m

10’+/10m+

10’+/10m+

10’+/10m+

eBridge4SPT User Interface and Programming:

Note: A constant PC connection is not required for proper operations and is used as a local programming/monitoring tool only.

Step 1. Set Local Area Connection of your laptop to DHCP mode.

For Windows XP:

a. Open Network Connections by clicking

Start button, then clicking Settings, then clicking Network Connections.

b. Right click the

Local Area Connection. Click Properties. Administrator permission required

If you are prompted for an administrator password or confirmation, type the password or provide confirmation.

c. Double click

Internet Protocol (TCP/IP) menu item.

d. Choose the

Obtain an IP address automatically option.

e. Click

OK. Close all windows.

For Windows Vista:

a. Open Network Connections by clicking the

Start button Picture of the Start button, clicking Control Panel,

clicking

Network and Internet, clicking Network and Sharing Center, and then clicking Manage Network

connections.

b. Right click the

Local Area Connection icon, and then click Properties. Administrator permission required

If you are prompted for an administrator password or confirmation, type the password or provide confirmation.

c. Click the

Networking tab. Under this connection uses the following items, click either Internet Protocol

Version 4 (TCP/IPv4) or Internet Protocol Version 6 (TCP/IPv6), and then click Properties.

d. To specify IPv4 IP address settings, click

Obtain an IP address automatically, and then click OK.

e. To specify IPv6 IP address settings, click

Obtain an IPv6 address automatically, and then click OK.

For Windows 7:

a. Open Network Connections by clicking the

Start button Picture of the Start button, clicking Control Panel,

clicking

Network and Internet, clicking Network and Sharing Center, and then clicking Change Adapter

Settings.

b. Right click the

Local Area Connection icon, and then click Properties. Administrator permission required

If you are prompted for an administrator password or confirmation, type the password or provide confirmation.

c. Click the

Networking tab. Under this connection uses the following items, click either Internet Protocol

Version 4 (TCP/IPv4) or Internet Protocol Version 6 (TCP/IPv6), and then click Properties.

d. To specify IPv4 IP address settings, click

Obtain an IP address automatically, and then click OK.

e. To specify IPv6 IP address settings, click

Obtain an IPv6 address automatically, and then click OK.

Step 2. Connect a laptop or PC to the Ethernet port of your eBridge4SPT unit, or connect your eBridge4SPT and

laptop/PC to a DHCP router if eBridge4SPT is in DHCP mode. The eBridge4SPT unit should be

powered up at this moment.

Step 3. Open a browser window (it is necessary to update your browser software to the latest version so that the pages

display and function correctly).

Step 4. Enter the eBridge4SPT IP address (the default IP address is 192.168.168.168), or enter the eBridge4SPT

host name if in DHCP mode (default host name is “eBridge4SPT1”,) into the address bar.

Status page will be displayed.

This manual is related to the following products: