Technical specifications – Altronix eBridge16CR Installation Instructions User Manual
Page 3
eBridge16CR
- 3 -
2. Unit should be located in proximity to ethernet switch/network, NVR or video server.
3. Connect UL Listed 24VAC Class 2 plug-in transformer or 24VDC/56VDC (polarity not observed) UL Listed
Class 2 power supply to jack marked [Power Input] using two pin plug in connector (supplied) (Fig. 1, pg. 2).
Use 22AWG-16AWG wire for this connection.
4. Connect structured cable from ethernet switch/NVR (network video server) to RJ45 jack marked [10/100BaseT]
(Fig. 1, pg. 2).
5. Connect Coax cable to BNC connector marked [Data In] (Fig. 1, pg. 2).
6. For optional simultaneous Composite Video transmission, connect Coax cable to BNC connector marked
[Composite Video Out] (Fig. 2, pg. 3). Connect the other end of the Coax cable to the composite video input of the
NVR, monitor display, matrix switch or other headend equipment.
Note: The eBridge is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important
to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a
PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may
show pixilation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be
reduced to accommodate system equipment.
Technical Specifications:
Parameter
Description
Connections
BNC for Coax link. RJ45 for ethernet link.
Composite video connector for optional composite video service
Input power requirements 24VDC/1500mA, 56VDC/700mA, 24VAC/2000mA.
Indicators
Blue: Coax Link.
Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.
Green: Power.
Environmental
Conditions
Operating Ambient Temperature: UL60950-1 14ºF to 122ºF (-10ºC to 50ºC).
Relative humidity: 85%, +/ --- 5%
Storage Temperature: --- 4º to 158ºF (--- 20º to 70ºC) Storage
Operating Altitude: --- 1000 to 6,561.679 ft. (--- 304.8 to 2000m).
Regulatory Compliance
UL/CUL Listed for Information Technology Equipment (UL 60950-1). CE approved.
Weights (approx.)
Product: 7.2 lbs. (3.27 kg.), Shipping: 9.2 lbs. (4.17 kg.)
Fig. 1
Structured Cable from
Ethernet Switch/NVR
24VDC/1500mA,
56VDC/700mA,
24VAC/2200mA
Back of Unit
Front of Unit
Coax Cable from
eBridge1CT or
Hybrid Camera/Device
Optional Composite
Video Connector
to Monitor