VEGABAR 81, tube isolating diaphragm
1.02"
1.26"
1.97"
DN
mm
PN
G1
L
25 40 Rd52x
1
/
6
"
Rd58x
1
/
6
"
Rd78x
1
/
6
"
G1
Rd52x
1
/
6
"
Rd58x
1
/
6
"
Rd78x
1
/
6
"
128
Mb
26
32 40
140
32
50 25
156
50
DN
inch
PN
L
25 40
32 40
50 25
Mb
1.12"
1.69"
2.15"
2.36"
2.36"
2.36"
2.48"
3.35"
3.74"
DN
mm
inch
PN
D
L
Mb
25 6…100
63
28,5
60
40 6…100
85
43
60
50 6…100
95
54,5
60
DN
PN
D
L
Mb
25 6…100
40 6…100
50 6…100
H3
H7
4.09" 0.39"
DN
mm
PN
G1
Mb
L
10 40
RD44x
1
/
6
"
RD28x
1
/
8
"
RD28x
1
/
8
"
RD44x
1
/
6
"
104
104
10
20 40
20
DN
inch
PN
G1
d
D
10 40
4.09" 0.79"
20 40
5.04"
5.51"
6.14"
1
2
3
89 mm (3.5")
MB
MB
G1
D
89 mm (3.5")
L
L
89 mm (3.5")
MB
G1
L
Fig. 52: VEGABAR 81, tube isolating diaphragm
1 Tube isolating diaphragm for mounting between flanges
2 Tube isolating diaphragm according to DIN 11851
3 Tube isolating diaphragm according to DIN 11864-1
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)