VEGA VEGAFLEX 86 Foundation Fieldbus User Manual

Page 39

background image

39

6 Set up with the display and adjustment module

VEGAFLEX 86 • Foundation Fieldbus

44233-EN-130910

In this menu item you can enter the probe length or have the length

determined automatically by the sensor system.
When choosing "Yes", then the probe length will be determined

automatically. When choosing "No", you can enter the probe length

manually.

In this menu item you can select which type of medium you want to

measure. You can choose between liquid or bulk solid.

In this menu item, you can select the application. You can choose

between level measurement and interface measurement. You can

also choose between measurement in a vessel or in a bypass or

standpipe.
Note:

The selection of the application has a considerable influence on all

other menu items. Keep in mind that as you continue with the param-

eter adjustment, individual menu items are only optionally available.
You have the option of choosing the demonstration mode. This mode

is only suitable for test and demonstration purposes. In this mode, the

sensor ignores the parameters of the application and reacts immedi-

ately to each change.

In this menu item, you can define the type of medium (product).
This menu item is only available if you have selected level measure-

ment under the menu item "Application".

You can choose between the following medium types:

Dielectric con-

stant

Type of medium Examples

> 10

Water-based liq-

uids

Acids, alcalis, water

3 … 10

Chemical mix-

tures

Chlorobenzene, nitro lacquer, aniline,

isocyanate, chloroform

Setup - Probe length

Setup - Type of medium

Setup - Application - Ap-

plication

Setup - Application - Me-

dium, dielectric constant