3 Product description

MINITRAC 31 • 4 … 20 mA/HART - four-wire

43389-EN-131119

The instrument is available in different electronics versions. Each ver-

sion can be identified via the product code on the type label:

Standard electronics type PT30E-XX

The scope of delivery encompasses:

Radiation-based sensor

Documentation

– this operating instructions manual

– Safety Manual (SIL) PROTRAC series 30 (Document-ID 42961)

– Operating instructions manual "Display and adjustment mod-

ule" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The instrument is suitable for applications in liquids in vessels also

under difficult process conditions. There are application possibilities

in nearly all areas of industry.
The measured value is detected contactlessly right through the vessel

wall. Neither a process fitting nor a vessel opening are required. The

instrument is thus ideal for retro installation.
The instrument is various application possibilities. Apart from the level

detection, the MINITRAC 31 can also detect residues.

1

2

Fig. 2: MINITRAC 31 - Application possibilities
1 Level measurement - Residue detection

2 Point level detection

In radiation-based measurement, a Caesium-137 or Cobalt-60 iso-

tope emits focussed gamma rays that are attenuated when penetrat-

ing the vessel wall and the medium. The NaI detector on the opposite

side receives the radiation. The intensity of the radiation depends

Electronics versions