5 Connecting to power supply

MINITRAC 31 • 4 … 20 mA/HART - four-wire

43389-EN-131119

5.3 Connection - Level measurement

Non-Ex instruments and instruments with non-intrinsically safe

current output

1

1

24

/L

/N

PE

56

91

01
1

22

11

12

21

22

19

20

18
17

14
13

16
15

12

2

3

1

4

6

5

Fig. 11: Electronics and connection compartment with non-Ex instruments and

instruments with non-intrinsically safe current output
1 Voltage supply

2 Relay output

3 Signal output 4 … 20 mA/HART active

4 Signal output 4 … 20 mA/HART passive

5 Interface for sensor-sensor communication (MGC)

6 Setting the bus address for sensor-sensor communication (MGC)

3)

5 6 7 8

2

1

Fig. 12: Adjustment and connection compartment with non-Ex instruments and

instruments with non-intrinsically safe current output
1 Terminals for the external display and adjustment unit

2 Contact pins for the display and adjustment module or interface adapter

Instruments with intrinsically safe current output

You can find detailed information on the explosion-protected versions

(Ex-ia, Ex-d) in the Ex-specific safety instructions. These safety

instructions are part of the scope of delivery and come with the Ex-

approved instruments.

Electronics and con-

nection compartment

- Non-Ex instruments and

instruments with non-

intrinsically safe current

output

Adjustment and con-

nection compartment

- Non-Ex instruments and

instruments with non-

intrinsically safe current

output

3)

MGC = Multi Gauge Communication