VEGA VEGADIF 65 4 … 20 mA_HART User Manual
Page 53
53
6 Adjustment with the display and adjustment module PLICSCOM
VEGADIF 65 • 4 … 20 mA/HART
36128-EN-130417
Part sum counter
0 % = +0000
m
3
/s=
100 % = +0000
m
3
/s=
6. Edit with [OK] and set the requested values with [+] and [->].
7. Confirm with [OK] and jump back to the indication of the part sum
counter.
8. Select with [->] the unit of the sum counter, adjust the requested
unit with [->], for example m
3
/s and confirm with [OK].
The setting of the part sum counter is hence terminated, the counting
function is activated.
The procedure of the total sum counter is the same.
This function enables uploading parameter adjustment data into the
display and adjustment module as well as downloading parameter
adjustment data into the sensor. A detailed description of the function
is available in the operating instructions manual "Display and adjust-
ment module".
The following data are loaded or downloaded with this function:
•
Measured value presentation
•
Applications
•
Adjustment
•
Damping
•
Linearization curve
•
Leak flow volume suppression
•
Sensor-TAG
•
Displayed value
•
Display unit
•
Scaling
•
Current output
•
Unit of measurement
•
Language
The following safety-relevant data are not uploaded or downloaded:
•
HART mode
•
PIN
Copy sensor data
Copy sensor data?
Basic adjustment
The reset "Basic adjustment" resets the values of the following menu
items to the reset values (see chart):
Copy sensor data
Reset