5 accessories and replacement parts – VEGA VEGADIF 65 4 … 20 mA_HART User Manual
Page 13
13
3 Product description
VEGADIF 65 • 4 … 20 mA/HART
36128-EN-130417
•
Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
•
Relative humidity 20 … 85 %
3.5 Accessories and replacement parts
The display and adjustment module PLICSCOM is used for measured
value indication, adjustment and diagnosis. It can be inserted into the
sensor and removed at any time.
You can find further information in the operating instructions "Display
and adjustment module PLICSCOM" (Document-ID 27835).
The interface adapter VEGACONNECT 4 enables the connection of
communication-capable instruments to the USB interface of a PC. For
parameter adjustment of these instruments, an adjustment software
such as PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface
adapter VEGACONNECT" (Document-ID 32628).
VEGADIS 61 is suitable for external measured value indication and
adjustment of plics® sensors. It is connected to the sensor with an up
to 25 m long, four-wire, screened standard cable.
You can find further information in the operating instructions "VE-
GADIS 61" (Document-ID 27720).
VEGADIS 62 is suitable for measured value indication and adjustment
of sensors with HART protocol. It is looped into the 4 … 20 mA/HART
signal cable.
VEGADIS 62 is suitable for measured value indication with sensors
without HART protocol.
You can find further information in the operating instructions "VE-
GADIS 62" (Document-ID 36469).
The protective cover protects the sensor housing against soiling and
intense heat from solar radiation.
You will find additional information in the supplementary instructions
manual "Protective cover" (Document-ID 34296).
The oval flange adapter enables the connection of a ½ NPT tube to a
VEGADIF 65 or a valve block. By selecting the suitable materials, the
oval flange adapter can be adapted to all processes.
You can find additional information in the supplementary instructions
"Mounting accessory pressure" (Document-ID 43478).
Valve blocks enable simple installation and setup of a differential
pressure transmitter. When the process valves are closed, the equali-
zation valve enables a pressure compensation for the measuring
chambers. This allows the zero point of the pressure transmitter to be
adjusted.
Storage and transport
temperature
Display and adjustment
module
Interface adapter
External display and
adjustment unit
External display and ad-
justment unit VEGADIS 62
Protective cap
Oval flange adapter
Valve blocks