VEGA PLICSRADIO T62 Wireless emitting unit User Manual
Page 34
34
10 Supplement
PLICSRADIO T62 • Wireless emitting unit (multiple channel)
32624-EN-130228
Ʋ Housing socket
– 3 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm)
or:
– 3 x closing cap ½ NPT
Ʋ Electronics housing
– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
antenna connection (R-SMA)
or:
– 1 x closing cap ½ NPT, 1 x antenna connection
(R-SMA)
Spring-loaded terminals
for wire cross-section up to 2.5 mm² (AWG 14)
Ambient conditions
Ambient, storage and transport tempera-
ture
-40 … +80 °C (-40 … +176 °F)
Electrical protective measures
Protection rating
Ʋ Plastic housing
IP 66/IP 67
Ʋ Aluminium housing
IP 66/IP 67
3)
Overvoltage category
III
Protection class depending of the power supply unit version
Ʋ 24 V version
II
Ʋ 115/230 V version
I
Electrical separating measures
Reliable separation according to VDE 0106 part 1 between power supply and input
Ʋ Reference voltage
253 V (50 V at 24 V power supply unit version)
Ʋ Isolation resistance
3.75 kV (1.5 kV with 24 V version of the power supply
unit)
Radio approvals
Radio approvals
Ʋ Standard version
FCC ID: OUR-24xSTREAM
Ʋ Version increased range
FCC ID: OUR-9xSTREAM
IC (Industry Canada)
Ʋ Standard version
4214A 12008
Ʋ Version increased range
4214A-9xSTREAM
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"
and "serial number search" as well as via "Downloads" and "Approvals".
3)
A suitable cable is the prerequisite for maintaining the protection rating.