5 Connecting to power supply
PLICSRADIO T62 • Wireless emitting unit (multiple channel)
32624-EN-130228
3. Remove the terminal cover by loosening the fixing screw
4. Loosen compression nut of the cable entry
5. Remove approx. 10 cm (4 in) of the cable mantle, strip approx.
1 cm (0.4 in) of insulation from the ends of the individual wires
6. Insert the cable into the sensor through the cable entry
7. Lift the opening levers of the terminals with a screwdriver (see
following illustration)
8. Insert the wire ends into the open terminals according to the wir-
ing plan
Fig. 8: Connection steps 6 and 7 (connect voltage supply)
9. Press down the opening levers of the terminals, you will hear the
terminal spring closing
10. Check the hold of the wires in the terminals by lightly pulling on
them
11. Tighten the compression nut of the cable entry. The seal ring must
completely encircle the cable
12. Insert and screw terminal cover
13. If a display and adjustment module is installed, insert it by turning
it slightly to the right.
14. Screw the housing cover back on
The electrical connection is hence finished.