2 ASCII protocol

Modbus-TCP, ASCII protocol • VEGAMET 391/624/625, VEGASCAN 693, PLICSRADIO C62

30768-EN-130701

Number of bytes

Character

End identification

1

CR

Identifier: "?" (1 character)

Start: No. of the requested PC/DCS output (1 … 3 characters)

Separator: "L" or "I" (1 sign)

Quantity: Number of requested PC/DCS outputs (1 … 3 signs)

End identification: Carriage Return CR (1 sign)

Total length of the telegram: 5 … 9 characters

"N"-times repetition of the following telegram

Number of bytes

Character

T1

1

=

DCS no.

3

001 … 030

T2

1

#

Value

7

-000673

T3

1

#

Unit

0 … n

xxx

End identification

1

CR

T1: "=" (1 character)

DCS no.: No. of the PC/DCS output as 3-digit decimal number

T2: "#" (1 character)

Value: Numerical value of the PC/DCS output or with interferred

measured value the text "FAULT"

Formatting of the value:

Character

Meaning

1

"- ": Minus with negative numbers
" ": Space with positive numbers

2 … 7

6-digit number after the decimal point

T3: "#" (1 character)

Unit: Unit as text (0 … n unit)

End identification: Carriage Return CR (1 sign)

Total length of the telegram: Number*(14 characters+Unit character)
Enquiry:

?001L003
Answer:

=001# 000673#%

=002# 008246#kg

=003#-000673#m

? Block enquiry with range

The range stated in the enquiry with PC/DCS values is delivered as

reply to the range enquiry. The measured value is transmitted with six

decimal places without decimal point and with unit.

Reply from the signal

conditioning instrument

Example: