2 overview of the commands and options – VEGA Modbus-TCP, ASCII protocol User Manual

Page 10

background image

10

2 ASCII protocol

Modbus-TCP, ASCII protocol • VEGAMET 391/624/625, VEGASCAN 693, PLICSRADIO C62

30768-EN-130701

Fig. 1: Connection via HyperTerminal

The setting of "telnet:\\192.168.200.200:503" in the address field

of the Internet Explorers starts the terminal program HyperTerminal

automatically. Max. four simultaneous connections are possible.

2.2 Overview of the commands and options

The following ASCII signs are interpreted as commands:

Command

Description

Version

Enquiry of the protocol version

help

Indication of the command formats

clearstore

Settings of the option Store will be deleted in the EEPROM

memory

%

Measured value enquiry with three places in front of the deci-

mal point and one place after the decimal point without unit

&

Measured value enquiry with six places after the decimal point

and without unit

?

Measured value enquiry with six positions after the decimal

point and with unit

$

Measured value enquiry with 11 places as floating point and

with unit

Note:

On the switching inputs of PLICSRADIO C62 (measurement loops

4 … 6) the values 0 (switch open) and 100 (switch closed) are trans-

mitted as measured values; the units are discarded.

Commands