beautypg.com

VEGA VEGASON 61 Foundation Fieldbus User Manual

Page 8

background image

8

3 Product description

VEGASON 61 • Foundation Fieldbus

28790-EN-130417

product surface and received back by the transducer as echoes.

The running time of the ultrasonic pulses from emission to reception

is proportional to the distance and hence the level. The determined

level is converted into an appropriate output signal and outputted as

measured value.

Power is supplied via the H1 Fieldbus. A two-wire cable according to

Fieldbus specification serves as carrier of both power and digital data

for multiple sensors. This cable can be operated in two versions:

via an H1 interface card in the control system and additional power

supply

via a Linking device with HSE (High speed Ethernet) and addi-

tional power supply according to IEC 61158-2

The DD (Device Descriptions) and CFF (capability files) necessary

for planning and configuration of your FF (Foundation Fieldbus) com-

munication network are available in the download area of the VEGA

homepage www.vega.com under "Services - Downloads - Software

- Foundation Fieldbus". The appropriate certificates are also available

there. A CD with the appropriate files and certificates can be ordered

via e-mail under [email protected] or by phone from one of the

VEGA agencies under the order number "DRIVER.S".
The backlight of the display and adjustment module is powered by the

sensor. Prerequisite is a certain level of operating voltage.
The data for power supply are specified in chapter "Technical data".
The optional heating requires its own operating voltage. You can find

details in the supplementary instructions manual "Heating for display

and adjustment module".
This function is generally not available for approved instruments.

3.3 Operation

The instrument can be adjusted with the following adjustment media:

With the display and adjustment module

with the suitable VEGA DTM in conjunction with an adjustment

software according to the FDT/DTM standard, e.g. PACTware and

PC

a configuration tool

3.4 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

based on ISO 4180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.

Power supply and bus

communication

DD/CFF