Veris Technologies 2000XA Soil EC Mapping System (1997-2008 CF card drive 1.77D) - Operating Instructions User Manual
Page 3
Veris Technologies
Pub. #OM 1CM02-1
3
2) Never allow anyone to ride on the implement during operation.
3) Lift the implement only with the provided ratchet jack.
4) Properly support the unit before performing any adjustment or maintenance.
5) Due to its small size and narrow design, it is not intended for high-speed travel on public
roads. If you choose to do so, contact your state Department of Transportation for safety
markings and guidelines. Veris Technologies suggests trailer transport.
Installation and Set-up
Instrument
The Veris EC Instrument Kit (PN 15161) includes the following:
Signal cable
Protective case
Test Box
Power Cable Test Load
Mounting Bracket
EC Instrument
Make sure that you have received all of these components in your EC Package.
Mount instrument in a location that is as free as possible from dust, vibration, and electrical
interference. Display should be visible to operator and shielded from direct sunlight.