beautypg.com

Rules for controller assignment, Main rules for xt2+ server – EVS XT2 Version 11.02 - July 2013 Configuration Manual User Manual

Page 107

background image

OSD

Description

Specifies which device (main or secondary controller) will
manage the OSD display characters in parallel mode.

Values

Two values are possible:

Main: The OSD display is managed by the main controller.

Sec.: The OSD display is managed by the secondary
controller.

Rules for Controller Assignment

Main Rules for XT2+ server

On an XT2+ server, the following main rules are applicable:

In a Multicam LSM base configuration:

All Remote Panels must be the first in the list of main controllers, without gap. It is
not allowed to have another controller preceding a Remote Panel in this list.

Other controllers can be assigned as secondary controllers to PGMs taking into
account the protocol-specific rules.

No more than 4 play channels on an EVS server can be assigned to Remote
Panels, and no more than 3 play channels can be assigned to one Remote Panel.

Only a Remote Panel (no other controller) can be assigned to a REC channel as a
main controller.

No secondary controller can be assigned to a REC channel.

In a Spotbox or Server base configuration:

A Remote Panel is not allowed.

Controllers other than the EVS Remote can be assigned to play or record
channels, taking into account the protocol-specific rules on controller use and
combinations.

CONFIGURATION MANUAL XT2+ Server 11.02

3. Multicam Configuration

99